cypress solutions CTM ONE Скачать руководство пользователя страница 5

 

 

© 2017 Cypress Solutions

     

Manual: CTM ONE (Revision 1.0)

  

 

 

Notice 

 

1

 

Notice 

Due to the nature of wireless communication, the reception or transmission of data can never be guaranteed. 
Data may be delayed, corrupted or never received. Data transfer problems are rare with well-constructed and 
configured wireless networks used in conjunction with devices such as the CTM ONE wireless data device. 
Cypress Solutions Inc. accepts no responsibility for damages of any kind including, but not limited to personal 
injury, death, or loss of property due to the delay or loss of data resulting from the use of the CTM ONE wireless 
data device.  
 

1.1

 

Operation in hazardous/restricted environments  

 
Wireless transmitters can cause interference with some critical operation equipment. For this reason it is 
required that the RF portion of the CTM ONE wireless data device be turned off when in the vicinity of blasting 
operations, medical equipment, life support equipment, or any other equipment that is susceptible to radio 
interference. The CTM ONE wireless data device must be turned off when on-board or in the vicinity of any 
aircraft. The FAA prohibits the use of wireless transmitter equipment at any time during aircraft flight.  
 

1.2

 

Regulatory restrictions 

CAUTION: Any modifications to the CTM ONE wireless data device not expressly authorized by Cypress Solutions 
Inc. may cause its regulatory approval status to become invalidated, thereby voiding your authority to use the 
product.  

The CTM ONE wireless data device contains a wireless module approved under FCC CFR 47 part 2.1091 and 
Industry Canada RSS-102 rules for operation as a mobile or fixed device with its specified antenna of gain ≤6dBi 
and from which a separation distance of at least 20 cm (8”) must be maintained from all persons at all times and 
during all modes of operation.  If external antennas are used the antennas used must not be co-located or 
operated in conjunction with any other antenna or transmitter. These rules are in place to prevent any possible 
hazard due to personal exposure to electromagnetic radiation.  

CTM ONE devices are designed to operate with the approved wireless module installed. The module has its own 
FCC and Industry Canada approval ID number. 

 

1.3

 

Electromagnetic Interference (EMI) – United States FCC Information 

This equipment has been tested and found to comply with limits for a class A digital device, pursuant to part 15 
of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a 
commercial installation. This equipment generates, uses, and can radiate radio frequency energy, and if not 
installed and used in accordance with the instructions, may cause harmful interference to radio communication. 
However, there is no guarantee that harmful interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, which can be determined by 

Содержание CTM ONE

Страница 1: ...CTM ONE MANUAL Model CTM ONE M PLUS Revision Revision 1 0 3066 Beta Avenue Burnaby B C V5G 4K4 Phone 604 294 4465 Fax 604 294 4471 support cypress bc ca...

Страница 2: ...2017 Cypress Solutions Manual CTM ONE Revision 1 0 2 Revision Control Revision Control Description Initials Rev Date Initial Release mm 1 0 26 FEB 2019...

Страница 3: ...ts GPIO Serial 8 3 3 Auxilliary and IButton 8 3 4 USB OTG On The Go port 8 3 5 CAN Bus port 8 3 6 Locking 3 Wire power connector with ignition sense 9 3 7 Multiple RF connectors SMA RP SMA 9 4 SIM Car...

Страница 4: ...232 Serial Access 23 6 4 Login 23 6 5 Web Interface 24 6 5 1 Dashboard 24 6 5 2 System Database 24 6 5 3 Installer 25 6 5 4 Firmware 25 6 5 5 Change Password 25 6 5 6 Configuration 26 7 Additional Fea...

Страница 5: ...gulatory approval status to become invalidated thereby voiding your authority to use the product The CTM ONE wireless data device contains a wireless module approved under FCC CFR 47 part 2 1091 and I...

Страница 6: ...n for help 1 4 Electromagnetic Interference EMI Canada Information This digital apparatus does not exceed the class B limits for radio noise emissions from digital apparatus as set out in the interfer...

Страница 7: ...2017 Cypress Solutions Manual CTM ONE Revision 1 0 7 Product Overview 2 Product Overview...

Страница 8: ...tion interface Inputs x 4 2 differential Outputs x 4 Console Command Line Interface access PAD host interface 1 available Virtual Serial Line replacement MODBUS host interface MODBUS interface Various...

Страница 9: ...M ONE supports two 2FF style SIM cards One or two SIMS can be installed For single SIM card installation we recommend use the upper sot of the dual SIM holder the UPPER Slot is the slot furthest away...

Страница 10: ...hat the gasket is in place when the Battery cover is reinstalled and tighten screws in a x cross pattern until snug for optimal weather tight seal Do not overtighten recommended torque value 4 5 in lb...

Страница 11: ...s may need to be used to provide adequate Cellular Wi Fi GNSS operation Optimal in vehicle mounting locations includes areas that have clear visibility of the sky such as under dash under window locat...

Страница 12: ...ket that has four 5mm mounting holes suitable for 10 screws Take care not to over tighten these screws and damage the bracket Once this has been installed in the required location clip the CTM ONE int...

Страница 13: ...43030 Crimp Terminals 20 24 AWG The CAN interface is used primarily to interface to Vehicle sub systems that support CAN communications This includes all small and light duty vehicles manufactured in...

Страница 14: ...ector Molex Part Number Description 43025 0400 Receptacle housing 43030 Crimp Terminals 20 24 AWG When a compatible vehicle interface is not available or not preferred the CTM can be connected with a...

Страница 15: ...this line using its ignition sense features When the ignition line is wired the CTM ONE does not completely shut down a small amount of power is used 1 2mW 40 mW to monitor the status of various input...

Страница 16: ...cm 8 The decision to use external antennas should be made based on performance evaluation of how the product performs when placed in the desired location within the vehicle or fixed site 5 5 1 Cellula...

Страница 17: ...NE s Ethernet port and the other end into the LAN device PC or Ethernet peripheral The Ethernet port is compatible with 10Base T or 100Base T connection types The Ethernet port support auto MDI MDIX m...

Страница 18: ...und of the 14 pins configured as Data Communication Equipment DCE RS485 uses two pins Serial data ports on most computer equipment are configured as Data Terminal Equipment DTE In some cases it may be...

Страница 19: ...e all input and outputs have transient protection The I O port provides for the control of 4 external devices and for monitoring 4 external inputs GPIO Block Pin Signal Name 1 INPUT1 Single Ended Inpu...

Страница 20: ...G Note that the OUT GND connection is connected to the CTM ONE s supply ground 5 8 2 GPIO Input Connection The 4 inputs may be configured in the CTM ONE for monitoring a digital DC voltage state or an...

Страница 21: ...ample of Digital Input wiring For analog voltage monitoring the measurement range is 0 to 10 volts with 10mV resolution The input can withstand up to 36 volts Note that the IN GND connection is refere...

Страница 22: ...0 connector Molex Part Number Description 43025 1000 Receptacle housing 43030 Crimp Terminals 20 24 AWG The auxiliary connection enables communication with Maxim iButton Devices and provides the abili...

Страница 23: ...ssword is CypressAccess CTM ONE Web interface is accessible by opening a browser to http 192 168 2 1 6 2 LAN0 Access When physically connected using an Ethernet cable the CTM ONE Web interface is acce...

Страница 24: ...rface The Web GUI is designed to be an intuitive system to view and change device settings 6 5 1 Dashboard The Dashboard shows general system settings 6 5 2 System Database The system database is a se...

Страница 25: ...A page typically used by installers to verify basic device functionality and available vehicle ECU CAN Bus Data 6 5 4 Firmware A page to locally install device firmware with a sub page for monitoring...

Страница 26: ...ual CTM ONE Revision 1 0 26 Accessing the CTM ONE 6 5 6 Configuration The Configuration page has folders that can be expanded to provide configuration details Note the Configuration page shown may var...

Страница 27: ...he device will spend most of its time in this mode triggers such as timer or input state change will bring the device out of this mode into Operating System mode Operating system 25 30mA Linux is oper...

Страница 28: ...by monitoring events such as Acceleration GPS location on board Geo Fence Time Speed Temperature Voltage Input events 7 2 Power Consumption The power consumption of the CTM ONE gateway will depend on...

Страница 29: ...Off Power Power status Full operating mode running of DC input Standby Device has no power SIM SIM Status Green using SIM1 Red using SIM2 No SIM installed Cellular connectivity disabled Cellular Indic...

Страница 30: ...d by default to auto connect to a cellular network If the CTM ONE determines that communication with the internal cellular radio module or device is not working it will attempt to reset the communicat...

Страница 31: ...ions Manual CTM ONE Revision 1 0 31 General Troubleshooting Operation Technical Support Cypress Solutions Service Support Group 1 844 462 9773 or 778 372 4603 5 00am to 5 00pm PST support cypress bc c...

Отзывы: