![cypress solutions CTM-200 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/cypress-solutions/ctm-200/ctm-200_manual_2706762009.webp)
Physical Interfaces
8
© 2021 Cypress Solutions
Complete Manual: CTM-200 R2 (Revision 1.4)
2.
Physical Interfaces
2.1
Ethernet
•
Two Ethernet ports (bridged/non-bridged)
•
Ethernet services can be disabled
•
Ethernet ports can use DHCP or static IP addresses, DHCP can be configured to a single IP address
•
Gateway support when an Ethernet port is used to connect to the Internet through another router
•
Static NAT support
•
Multi-wan support for special packet routing configurations
2.2
General Purpose Input and Outputs
•
One General Purpose 18 position Input and Output interface
•
Inputs x 6 (2 differential)
•
Outputs x 4
•
Wiegand/iButton™ interface
2.3
RS-232 serial port
•
Console, Command Line Interface access
•
PPP, dial up over serial (legacy)
•
PAD host interface (2 available), Virtual Serial Line replacement
•
MODBUS host interface, MODBUS interface
•
Serial Access Control (RFID) interface, Access control hardware interface
•
Various Spreader Controller models, Spreader controller interface
•
External GPS receiver, Add a high precision GPS receiver input
•
Garmin™ Personal Navigation Devices, Interface for in vehicle display
•
Auxiliary Equipment Interface
•
Inputs x 2
•
Outputs x 2
2.4
USB OTG (On-The-Go) port
•
For future implementation