87
8.3 Application Notes
►
The unit’s default IP address is 192.168.1.50.
►
4K UHD sources or equivalently high-bandwidth signals require an
appropriate compatible display and Premium High Speed HDMI or
certified DisplayPort 1.2 cables in order to achieve the best image
quality.
►
HDBaseT requires Cat.5e, Cat.6, or Cat.7 certified cable. Cat.6 or better
is highly recommended.
►
The collaboration Transmitter’s analog audio input can only be
embedded into video sources connected to the Transmitter (VGA,
HDMI, DP). It is not possible to embed the analog audio into the HDMI
source connected to the Receiver.
►
Due to the large amount of data that needs to be processed,
the WebGUI’s Event, Macro, Command, and Device tabs do not
automatically update while they are being viewed. Please manually
refresh or reload the web page to immediately update the displayed
info (press F5 in most browsers).
►
The Command Data field supports up to a maximum of 256
characters. Note that some captured IR commands might exceed this
limit, and their data will be truncated.
►
The serial port (RS-232) on the Transmitter may be used for events,
however, the baud rate is locked at 115200bps to maintain support for
controlling the Transmitter itself via RS-232.
►
Listening for multiple Serial Port (RS-232) events is supported,
however, all active events using the Receiver’s RS-232 port must use
the same baud rate. It is not possible for multiple active events to
listen at different baud rates.
►
IR receiver events can select Local (Transmitter) or Remote (Receiver)
to identify the location of the IR interface to use.
►
Some VGA and DisplayPort sources might not support the “Plug In”,
“Plug Out” or “Plug Change” event conditions because the 5V line used
for input detection is optional on those interfaces.
►
The Auto Audio Switch function makes its decision based on if the
signal contains audio packets or not. If the source contains audio
packets, but it is set to mute or volume equals 0, then it will still
determine that audio is present.