![CYP CPLUS-V2PEL Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/cyp/cplus-v2pel/cplus-v2pel_operation-manual_2705231029.webp)
24
COMMAND
Description and Parameters
N2
= A ~ B
[Target output port]
N3
= ON, OFF
[Enable/Disable event type]
GET AUTOMATION EVENT N1 CEC N2
Show the current state of CEC automation event type
N1
.
Available values for
N1
:
1
[Power on]
2
[Out A sync active]
3
[Out A sync lost]
4
[Out B sync active]
5
[Out B sync lost]
N2
= A ~ B
[Target output port]
SET AUTOMATION EVENT N1 CEC N2 COMMAND N3
Set the CEC command to send when automation event
N1
is
triggered.
Available values for
N1
:
1
[Power on]
2
[Out A sync active]
3
[Out A sync lost]
4
[Out B sync active]
5
[Out B sync lost]
N2
= A ~ B
[Target output port]
Available values for
N3
:
0
[TV power off]
1
[TV power on]
Содержание CPLUS-V2PEL