20

8. SPECIFICATIONS

8.1 Technical Specifications

Input Ports

1×Optical In (TOSLINK) 
1×Line In (3.5mm) 
1×Mic In (3.5mm)

Output/Control Port

1×Ethernet (RJ-45)

Pass-through Port

1×RS-232 (3-pin Terminal Block)

Baud Rate

Up to 115200

Power Supply

5V/1.2A DC 

(US/EU standards, CE/FCC/UL certified)

 

or 
PoE (802.3af)

ESD Protection (HBM)

±8kV (Air Discharge) 
±4kV (Contact Discharge)

Dimensions (W×H×D)

108mm×25mm×108mm [Case Only]

 

108mm×25mm×116mm [All Inclusive]

Weight

370g

Chassis Material

Metal (Aluminum)

Chassis Color

Black

Operating Temperature

0˚C – 40˚C/32˚F – 104˚F

Storage Temperature

-20˚C – 60˚C/-4˚F – 140˚F

Relative Humidity

20 – 

90% RH (Non-condensing)

Power Consumption

2.27W

Содержание CH-A320TX

Страница 1: ...Operation Manual Operation Manual Audio over IP Transmitter CH A320TX ...

Страница 2: ......

Страница 3: ...Technology reserves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrieval system or any of its part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without expr...

Страница 4: ...d into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect the unit from overheatin...

Страница 5: ... Front Panel 3 6 2 Rear Panel 4 6 3 RS 232 Pinout 4 6 4 WebGUI Control 5 6 4 1 System Tab 6 6 4 2 Network Tab 9 6 4 3 Functions Tab 11 6 5 Telnet Control 13 6 6 Telnet Commands 13 7 Connection Diagram 19 8 Specifications 20 8 1 Technical Specifications 20 8 2 Audio Specifications 21 8 2 1 Digital Audio 21 8 2 2 Analog Audio 21 9 Acronyms 22 ...

Страница 6: ... sources to compatible audio playback devices located anywhere on the local network Standard control is provided by front panel controls WebGUI and Telnet Advanced control and system integration is possible using the optional IP Master Controller 2 APPLICATIONS Home Theaters Classrooms Lecture Halls 3 PACKAGE CONTENTS 1 Audio over IP Transmitter 1 5V 1 2A DC Power Adapter 1 3 pin Terminal Block 1 ...

Страница 7: ...ork switches Gain control for the microphone input Compatible with the IP Master Controller to allow integration with existing compatible TCP IP video matrix networks Field upgradable firmware May be powered directly by Power over Ethernet PoE when connected to a Gigabit Ethernet switch that provides PoE 802 3af Standard control is provided by front panel controls WebGUI and Telnet Advanced contro...

Страница 8: ... flash When the transmitter has established a stable connection the LINK LED will illuminate solidly 3 OPT LINE MIC LEDs The illuminated LED indicates which source is currently selected 4 MUTE LED This LED will illuminate when audio output is muted 5 MUTE Button Press to toggle between muting and unmuting the audio output 6 GAIN AUDIO SELECT Knob Turn this knob to increase or decrease the audio ga...

Страница 9: ... or other serial control device with a 3 pin adapter cable for the extension of RS 232 signals to a compatible receiver 5 LAN POE Port Connect via a Gigabit Ethernet switch to compatible receiver s to transmit data and to a PC laptop to control the unit via WebGUI Note This unit can be powered directly by the connected Gigabit Ethernet switch if it provides PoE 802 3af 6 DC 5V Port Plug the 5V DC ...

Страница 10: ...ress can be verified using the Device Discovery software By clicking on one of the listed devices you will be presented with the network details of that particular device 1 IP Mode If you choose you can alter the static IP network settings for the device or switch the unit into DHCP mode to automatically obtain proper network settings from a local DHCP server To switch to DHCP mode please select D...

Страница 11: ...are Once you have connected to a unit s WebGUI you will be presented with a screen containing multiple tabs for each functionality area of the unit To view the contents of a tab click on the appropriate button at the top of the window The individual tabs and functions will be introduced in the following sections Note A Gigabit Ethernet network switch with IGMP snooping is required when using multi...

Страница 12: ...egin the update process 3 Utilities The Utilities window allows users to reset the unit back to the factory defaults by clicking Factory Default The unit may be rebooted without resetting settings by pressing the Reboot button Finally individual Telnet commands may be sent to the unit by using the Console API Command text entry field and pressing Apply Any responses from the unit will be displayed...

Страница 13: ...istics The Statistics window shows all available information about the operational status of the unit including current Host ID Name Ethernet information MAC address unicast multicast mode link status and mode ...

Страница 14: ...ns in the WebGUI Note If the IP address is changed then the IP address required for WebGUI access will also change accordingly If the new address is assigned via Auto IP or DHCP it can be verified using the Device Discovery software 1 Channel Setup Use the dropdown to select the broadcast channel for the transmitter All receivers on the local network that are set to the same channel will receive a...

Страница 15: ...ting Show Me will cause the unit to immediately begin flashing the PWR and LINK LEDs on the front of the unit to make it easy to find Selecting Hide Me returns the LEDs to their normal behavior This setting is useful when troubleshooting an installation with a large number of units in a rack 3 Casting Mode Allows for the selection of the broadcasting mode used by the transmitter Click the Apply bu...

Страница 16: ...ial control extension configuration Changes made to these settings typically require a reboot of the unit After clicking on Apply please follow the reboot instructions in the WebGUI if necessary 1 Audio over IP This section allows control over selection of the input source enabling disabling the audio mute changing the microphone gain and front panel locks ...

Страница 17: ...his is only controllable when Mic In is the selected source Front Panel Lock for Device Button and Knob Enable or disable either of these lock types for the front panel When the locks are enabled the user can only change settings using the WebGUI or Telnet commands 2 Serial over IP Set the desired baud rate data bits parity and stop bit for the RS 232 signal to extend Note The transmitter and rece...

Страница 18: ...sh to control and commands may now be entered directly Note 1 If the IP address of the unit is changed then the IP address required for Telnet access will also change accordingly Note 2 This unit defaults to Auto IP mode The current IP address can be verified using the Device Discovery software The default communication port is 23 6 6 Telnet Commands COMMAND Description and Parameters help Show th...

Страница 19: ...defaults set factory ipconfig default Reset the unit s network settings to the factory defaults set system reboot Reboot the unit set keylock N1 Enable or disable the front panel button key lock feature Available values for N1 ON Key lock enabled OFF Key lock disabled get keylock Show the current front panel button key lock state set audio volume knob lock N1 Enable or disable the front panel volu...

Страница 20: ...ud 2400 2400 baud 4800 4800 baud 9600 9600 baud 19200 19200 baud 38400 38400 baud 57600 57600 baud 115200 115200 baud get uart 1 baudrate Show the current baud rate of the RS 232 port set uart 1 stop bit N1 Set the number of stop bits for the RS 232 port Available values for N2 1 1 Stop Bit 2 2 Stop Bits get uart 1 stop bit Show the current number of stop bits of the RS 232 port set uart 1 data bi...

Страница 21: ...t ip mode N1 Set the unit s IP address assignment mode Available values for N1 STATIC Static IP mode DHCP DHCP mode FORCE IP Auto IP mode get ip mode Show the current IP address assignment mode get ipconfig Show the unit s current IP configuration information get ip addr Show the unit s current IP address get netmask Show the unit s current netmask get gateway Show the unit s current gateway addre...

Страница 22: ...way address get static gateway Show the unit s current static gateway address set audio out A route N1 Route the specified audio input to the streaming output Available values for N1 1 Optical input 2 Line input 3 Mic input get audio out A route Show the current audio input routed to the streaming output set audio in 3 pre gain N1 Set the gain level for the mic input N1 0 100 Mic gain get audio in...

Страница 23: ...ansmission channel set showme N1 Enable or disable the unit s LEDs blinking to more easily visually identify the unit Available values for N1 ON Enabled OFF Disabled get showme Show the current state of the showme function set stream cast mode N1 Set the AoIP transmitter s network broadcast mode Available values for N1 UNICAST Unicast mode MULTICAST Multicast mode get stream cast mode Show the AoI...

Страница 24: ...N POE RS 232 TX RX DC 5V OUT R L G OPTICAL LINE IN MIC RS 232 LAN POE TX RX DC 5V Blu ray Player Network Switch Blu ray Player Microphone RS 232 Equipped PC Latop Power Supply Power Supply Powered Speakers Powered Speakers RS 232 Controllable Unit ...

Страница 25: ... Power Supply 5V 1 2A DC US EU standards CE FCC UL certified or PoE 802 3af ESD Protection HBM 8kV Air Discharge 4kV Contact Discharge Dimensions W H D 108mm 25mm 108mm Case Only 108mm 25mm 116mm All Inclusive Weight 370g Chassis Material Metal Aluminum Chassis Color Black Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 60 C 4 F 140 F Relative Humidity 20 90 RH Non condensing Po...

Страница 26: ... Channels 2 Channels Sampling Rate kHz 32 44 1 48 88 2 96 176 4 192 Bitstream Supported Formats Standard 8 2 2 Analog Audio Analog Input Line In Max Audio Level 2Vrms Impedance 19kΩ Type Unbalanced Analog Input Mic In Max Audio Level 2Vrms Impedance 16kΩ Type Unbalanced ...

Страница 27: ... Line Interface DAC Digital to Analog Converter dB Decibel DHCP Dynamic Host Configuration Protocol GbE Gigabit Ethernet Gbps Gigabits per second GUI Graphical User Interface IGMP Internet Group Management Protocol IP Internet Protocol kHz Kilohertz LAN Local Area Network LED Light Emitting Diode LPCM Linear Pulse Code Modulation MAC Media Access Control MHz Megahertz OPT Optical PD Powered Device...

Страница 28: ...23 ACRONYM COMPLETE TERM TCP Transmission Control Protocol THD N Total Harmonic Distortion plus Noise VLAN Virtual LAN Ω Ohm ...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...CYPRESS TECHNOLOGY CO LTD www cypress com tw ...

Отзывы: