3
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Transmitter Front and Rear Panels
Power
Link
Lite
CAT 5e /6 Out
DC 24V
IR2 Extender
RS232 In
IR1 Blaster
HDMI In
Rear
Front
2
3
1
5
4
6
7
8
1
RS232 In:
Connect to a PC/laptop or RS-232 control device
(with supplied 3.5 mm mini-jack to D-sub 9-pin adaptor) for the
transmission of RS-232 commands.
2
IR2 Extender:
Connect an IR extender cable for IR signal reception.
Ensure that remote control being used is within the direct line-of-
sight of the IR extender
.
3
IR1 Blaster:
Connect an IR blaster cable for IR signal transmission.
Place the IR blaster in direct line-of-sight of the equipment to be
controlled.
4
HDMI In:
Connect to the HDMI source equipment such as a DVD or
Blu-ray player.
5
DC 24V:
Connect the 24V DC power supply to the unit and plug
the adaptor into an AC outlet.
6
Link LED:
The yellow LED will illuminate when both the input and
output CAT5e/6/7 signals are connected. The LED will blink when
there is an error with the transmission signal.
7
Power LED:
This green LED will illuminate when the device is
connected to a power supply.
8
CAT5e/6 Out:
Connect to the receiver unit with a single CAT5e/6/7
cable for transmission of all data signals.
Содержание CH-506RXPL