44
COMMAND
Description and Parameters
get automation event N1 ir A delay
Show the delay time for the specified Automation Event’s IR response.
Available values for
N1
:
1
[Power
on]
2
[Output
A
source
active]
3
[Output
A
source
lost]
set automation event N1 ir A wait N2
Set the length of time to wait after an Automation Event’s IR response
has been activated before ANY other Automation Event can be
detected.
Available values for
N1
:
1
[Power
on]
2
[Output
A
source
active]
3
[Output
A
source
lost]
N2
= 0~240
[Wait seconds]
get automation event N1 ir A wait
Show the wait time for the specified Automation Event’s IR response.
Available values for
N1
:
1
[Power
on]
2
[Output
A
source
active]
3
[Output
A
source
lost]
set automation event N1 ir A learn
Learn the IR command to send when the specified Automation Event is
activated.
Available values for
N1
:
1
[Power
on]
2
[Output
A
source
active]
3
[Output
A
source
lost]