Operation Manual
Axro binder
Page 22
7.3.
Basic settings
Figure 11: Basic settings
7.3.1.
Alignment at the reference point
The binder must be aligned correctly at the reference point if a suitable knot is to be tied. The
binder is adjusted to the correct setting in the factory. However, after maintenance it may be
necessary to realign the binder at the reference point. The procedure is as follows:
Turn the Allen key in the indicated direction until the reference mark on the drive wheel is
aligned with the pointer (A).
7.3.2.
Checking the setting of the rotor
The rotor (C) has two reference marks.
The rotor turns 180 degrees each time product is bound. The reference marks are at 180
degrees to each other, and consequently the adjustment can be made using either reference
mark.
When the reference mark on the drive wheel is aligned with the pointer the reference mark on
the rotor (C ) must be aligned with the reference mark on the stator (D) (this situation is
shown in Fig. 11)
If the setting of the rotor is not correct, then the procedure is as follows:
For Parts & Service 1-877-862-6699