7
V1.3
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω
resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the
last fixture.
Art-Net Connection
Connect the Ethernet inputs of all fixtures with the Ethernet network.
Switch/Router
PC/Controlle
r
Art-Net
Art-Net
Occupation of the RJ45-connection:
PR-350S installs two RJ45 connectors for DMX data transmission. Pin 1 is for data +, Pin 2 for data -,
Pin 7 & 8 for earthing.
1
2
3
4
5
6
7
8
Ground
-
+
NET IN
+
-
Ground
1
2
3
4
5
6
7
8
NET OUT
Power connection
Power Requirements
The PR-350S luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains
an auto-ranging power supply.
Power linking between fixtures:
The fixture with powercon in and out socket. Connect the power out to the power in socket in the next
fixture till all are connected.
Caution: maximum power linking - 6 units.
Connection with the mains:
Connect the device to the mains with the enclosed power supply cable.
Содержание PR-350S