Installation

Read ‘Safety information’ before installing the fixture.

The fixture is designed for indoor use only and must be used in a dry location with adequate ventilation. 

Ensure that none of the fixture’s ventilation slots are blocked.

Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it where it can 

be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, 

secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if 

the primary fastening method fails.

Fastening the fixture to a flat surface

The fixture can be fastened to a hard, fixed, flat surface that is oriented at any angle. Ensure that the 

surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment to 

be installed on it.

Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or fall over. 

If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed 

below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails.

Mounting the fixture on a truss

The fixture can be clamped to a truss or similar rigging structure in any orientation. When installing the 

fixture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in 

any other orientation, you must use a half-coupler clamp that completely encircles the truss chord.

To clamp the fixture to a truss:

1. 

Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment 

to be installed on it.

2.  Block access under the work area.

3.  Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting 

bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting 

bracket legs and be fastened with a self-locking nut.

4. 

Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp 

securely.

5. 

Secure the fixture with a safety cable as directed below.

Securing with a safety cable

Secure the fixture with a safety cable (or other secondary attachment) that is approved for the weight of 

the fixture so that the safety cable will hold the fixture if a primary attachment fails.Loop the safety cable 

through the eyebolt in the back of the fixture and around a secure anchoring point. Do not loop the safety 

cable around the fixture’s mounting bracket only, as this will leave the fixture unsecured if it separates 

from the bracket.

DMX-512 connection/connection between fixtures
Occupation of the XLR-connection:

Содержание PAR-100UV

Страница 1: ...USER MANUAL PAR 100UV 100 watts powered UV COB PAR...

Страница 2: ...a truss 4 Securing with a safety cable 4 DMX 512 connection connection between fixtures 4 Power connection 5 Operation 5 Control Menu Map 5 Addressing 6 Universal DMX Control 6 RDM control 6 Zoom fun...

Страница 3: ...of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation oper...

Страница 4: ...n be clamped to a truss or similar rigging structure in any orientation When installing the fixture hanging vertically down you can use an open type clamp such as a G clamp When installing in any othe...

Страница 5: ...ed between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120...

Страница 6: ...starting address for all fixtures or a group of fixtures or make different address for each fixture individually If you set the same address all the units will start to listen to the same control sig...

Страница 7: ...ion allows you to adjust the beam width of the fixture manually Simply rotate the rotary knob in the display panel to control the zoom right stop maximum spot left stop minimum spot DMX Protocol 1 Cha...

Страница 8: ...address DMX value Function DMX value Function DMX value Function 000 009 ID1 ID66 212 ID23 235 ID46 010 019 ID1 213 ID24 236 ID47 020 029 ID2 214 ID25 237 ID48 030 039 ID3 215 ID26 238 ID49 040 049 I...

Страница 9: ...solution Do not rub glass surfaces hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tiss...

Страница 10: ...m Net weight 3 Kg Color Black Housing Aluminum IP rating 20 Operating temperature 5 C 45 C www cyclopslighting com Model PAR 100UV Light source 100 watts UV COB LED LED life expectancy 50 000 Hrs Beam...