background image

3

Version 1.0

Caution!

Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric 

shock when touching the wires!

Avoid looking directly into the light source!

Wear protective glasses and other PPE (personal protective equipment) when working on or near 

the fixture.

For your own safety, please read this user manual carefully before you initial start-up.

Follow operating safety precautions and pay attention to warning signs methods and equipment 

on the user manual.

Indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture. IP 

20 rating.

The ambient temperature must always be between -5° C and +45° C. 

Always make sure you are connecting this product to the proper voltage in accordance with the 

specifications in this manual or on the product’s specification label.Make sure it is grounded when 

using it!

Unplug mains lead before opening the housing!

Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture 

and the powercord from time to time.

Make sure to replace the fuse with another of the same type and rating.

Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot 

during operation. After use, wait for a cool-down period of at least 10 minutes before handling or 

transporting the device.

Every person involved with the installation, operation and maintenance of this device has to

- be qualified

- follow the instructions of this manual

- consider this manual to be part of the total product

- keep this manual for the entire service life of the product

- pass this manual on to every further owner or user of the product

- download the latest version of the user manual from the Internet

Introduction

Thank you for having chosen FR-150C. You will see you acquired a powerful and versatile device.

Unpack your item. Before you initial start-up, please make sure that there is no damage caused by 

transportation. Should there be any, consult your dealer and do not use the device.

Safety instructions

This device has left our premises in absolutely perfect condition. In order to maintain this condition and 

to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and 

warning notes written in this user manual. Always disconnect from the mains, when the device is not in 

use or before cleaning it. Keep away children and amateurs from the device! There are no serviceable 

parts inside the device. Maintenance and service operations are only to be carried out by authorized 

dealers.

Содержание FR-150C

Страница 1: ...USER MANUAL FR 150C 150 watts COB Cool White LED Powered Fresnel ...

Страница 2: ...ecuring with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Control Menu Map 6 Addressing 7 Universal DMX Control 7 RDM control 7 Zoom 8 DMX Protocol 8 ID address selection 9 Fixture Cleaning 9 Fuse Replacement 10 Troubleshooting 10 The fixture does not work no light 10 Technical specifications 11 Table of contents ...

Страница 3: ...ts of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of t...

Страница 4: ...rsion 1 0 Overview Safety cable anchor point Zoom knob Yoke Accessories clip Yoke locking knob Lens Dmx out Dmx in Power out Power in On off switch Enter button Down button Up button Menu button LED display ...

Страница 5: ... access under the work area 3 Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting bracket The bolt used must be M10 grade 8 8 steel minimum It must pass through both mounting bracket legs and be fastened with a self locking nut 4 Working from a stable platform hang the fixture with its clamp on the truss and fasten the clamp securely 5 Secure the fixtur...

Страница 6: ... into a 3 pin XLR plug and plug it in the DMX output of the last fixture Power connection Power Requirements The FR 150C luminaire operates on 100 to 240 volts AC 10 auto ranging The luminaire contains an auto ranging power supply Power linking between fixtures The fixture with powercon in and out socket Connect the power out to the power in socket in the next fixture till all are connected Cautio...

Страница 7: ...will start to listen to the same control signal from the same channel number In other words changing the settings of one channel will affect all the fixtures simultaneously If you set a different address each unit will start to listen to the channel number you have set based on the quantity of control channels of the unit That means changing the settings of one channel will affect only the selecte...

Страница 8: ...backward Step 3 Tighten the zoom button DMX Protocol 1 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer 2 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer CH2 Strobe 000 255 strobe with speed increasing 3 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer CH2 Strobe 000 255 strobe with speed increasing CH3 Dimmer mode 000 050 Dimme...

Страница 9: ...ID30 242 ID53 080 089 ID8 220 ID31 243 ID54 090 099 ID9 221 ID32 244 ID55 100 109 ID10 222 ID33 245 ID56 110 119 ID11 223 ID34 246 ID57 120 129 ID12 224 ID35 247 ID58 130 139 ID13 225 ID36 248 ID59 140 149 ID14 226 ID37 249 ID60 150 159 ID15 227 ID38 250 ID61 160 169 ID16 228 ID39 251 ID62 170 179 ID17 229 ID40 252 ID63 180 189 ID18 230 ID41 253 ID64 190 199 ID19 231 ID42 254 ID65 200 209 ID20 232...

Страница 10: ... cotton swab moistened with glass cleaner or distilled water 4 Check that the fixture is dry before reapplying power Fuse Replacement This fuse is located in a fuseholder next to the MAINS OUT socket on the connections panel To replace a fuse 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Unscrew the cap of the fuseholder and remove the fuse Replace with a fuse ...

Страница 11: ...x 2m 10 5 Dimmer curves Strobe Video flicker free with selectable PWM Silent operation Barn doors included Control protocols DMX RDM Control channels 1 2 3 4 CHs Input voltage AC100 240V 50 60Hz DMX connections 3 pin XLR In Out male and female Power connections PowerCon In Out Dimensions 384 x 296 x 347mm Net weight 6 Kg Color Black Housing Aluminum IP rating 20 Operating temperature 5 C 45 C www ...

Отзывы: