Error 6 - Membrane Fault (Stuck Key)
Cause:
Membrane is showing a key constantly activated (noticed at power-up.)
Service:
• Check the membrane and thumb controls for signs of fatigue, cracking, or possible moisture intrusion.
• Ensure the membrane connector is fully seated.
• Inspect the membrane cable for cuts, pinches, and all leads are fully inserted in their connectors.
• Replace the membrane and/or the thumb control switches.
Key list
Left and Right controls
Description
Key
Incline Down
1
Incline Up
2
Speed Down
3
Speed Up
4
Main controls
Description
Key
Volume Up
5
Volume Down
6
Channel Up
or
Next
7
Channel Down
or
Previous
8
STOP
9
Fan
10
700 series membrane
Page 84 of 261
Cybex 770T/790T Treadmill Part Number
Содержание CardioTouch 770T
Страница 1: ...Cybex 770T 790T Treadmill Service Manual www cybexintl com ...
Страница 8: ...Page 8 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 79: ...Flowchart Error 2 Page 79 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 82: ...Flowchart Error 4 Page 82 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 85: ...Flowchart Error 6 Page 85 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 89: ...Flowchart Error 9 Page 89 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 93: ...Flowchart Error 12 Page 93 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 95: ...Flowchart Error 13 Page 95 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 97: ...Flowchart Error 14 Page 97 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 99: ...Flowchart Error 15 Page 99 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 101: ...Flowchart Error 16 Page 101 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 255: ...Schematics Schematic 770T LED Display Page 255 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 256: ...Schematic 770T E3 View Monitor Page 256 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 257: ...Schematic 770T Cybex GO Page 257 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 258: ...Schematic 790T LED Display Page 258 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 259: ...Schematic 790T E3 View Monitor Page 259 of 261 Cybex 770T 790T Treadmill Part Number ...
Страница 260: ...Schematic 790T Cybex GO Page 260 of 261 Cybex 770T 790T Treadmill Part Number ...