3.
Torque Specs.
Qty.
Item
13 FT-LBS (17.6 Nm)
1
19
1
20
Tank Filling
Caution:
Use a drop cloth under the tank when filling to avoid staining floor or carpet.
Caution:
Do not fill past the calibration mark as indicated on the tank level sticker or water spillage can
occur.
• Remove black plug only for filling. Fill at MAX
resistance
+
sign only.
• Once filling is complete, insert tank plug into place.
Warning:
Do not insert fingers into tank!
1.
Filling requires a large bucket (not supplied) and the Fluid Rower Siphon (included). Filling will take
approximately 4.5 gallons (17 liters) of water.
2.
Remove the tank plug on top of tank and insert the flexible tube into the rear of the tank while keeping the
rigid hose in the bucket.
Note:
Where water quality is known to be poor, Cybex recommends the use of distilled water.
3.
Move the adjuster knob to the plus sign (+), and begin filling. Note: The siphon valve must be closed to allow
siphoning action to occur. Tip: Placing the bucket in an elevated position will allow the siphon to continually
pump water into the tank. Do not fill past the calibration mark indicated on the tank!
Note:
Opening the siphon valve will stop the pumping action. Use this feature to avoid water spillage
when nearing filling completion.
4.
Once filling is complete (to the proper calibration level as indicated on the tank), follow water treatment
schedule as shown.
Page 14 of 25
Содержание 30HR1
Страница 1: ...Hydro Rower 30HR1 Owner s Manual Part Number 1004358 0001 AA...
Страница 2: ......
Страница 12: ...9 10 Add Water Qty Item 1 17 4 5 GALLONS 17 LITERS 8 21 11 Qty Item 1 16 Page 12 of 25...
Страница 13: ...12 Optional Stand Instructions 1 Qty Item 1 19 1 20 2 Torque Specs Qty Item 7 FT LBS 9 5 Nm 1 20 Page 13 of 25...