Step 1.
Run the bundled CD disc or download the driver from the link below :
http://www.austin-hughes.com/resources/driver/rackmount-display
Step 2.
Double click the Setup.exe
Step 3.
Follow the installation instruction to finish the setup
Step 4.
After installation, run the TouchKit program & the “4 point calibration”
Please follow the below steps to setup the touch screen:-
Please do the initial calibration
after the first setup
Model
12V
24V
48V
125V
Input rating
Input voltage:
12-Volt
24-Volt
48-Volt
110-Volt
Input range:
9 ~ 18V
18 ~ 36V
36 ~ 75V
66 ~ 160V
Input current
- No load
50 mA
50 mA
50 mA
35 mA
- Full load
7183 mA
3551 mA
1755 mA
749 mA
Output rating
Output voltage:
12-Volt
12-Volt
12-Volt
12-Volt
Output current:
6.25A
6.25A
6.25A
6.25A
Efficiency
87%
88%
89%
91%
< 3.5 > Options : DC Power
( 1 )
If the unit with LCD, earthing may be required
For DC power option :
***
TRB Driver
< 3.4 > Options : Touchscreen & driver