Fan test – Press the
mode
button repeatedly until the fan light comes
on. The fan should turn on. Note: if you have re-purposed your fan
(green) wire to be used as ‘C’ wire then this test will not work.
Cooling test – Press the
mode
button repeatedly until the cool light
comes on. Press the
up
or
down
buttons to select a temperature lower
than the room temperature. The air conditioner should turn on.
Heating test – Press the
mode
button repeatedly until the heat light
comes on. Press
up
or
down
buttons to select a temperature higher
than the room temperature. The first stage heater should turn on. After
some time, second stage heater (if available) should turn on.
Note: For system safety and performance, heating and cooling cannot
be used back to back. Please allow at least fifteen minutes between
heating and cooling tests. Power cycling
CyberStat
will overcome this
time delay.