CyberResearch CYDIO 96P Скачать руководство пользователя страница 38

Warranty Notice

CyberResearch, Inc. warrants that this equipment as furnished will be free from
defects in material and workmanship for a period of one year from the confirmed
date of purchase by the original buyer and that upon written notice of any such
defect, CyberResearch, Inc. will, at its option, repair or replace the defective item
under the terms of this warranty, subject to the provisions and specific exclusions
listed herein.
This warranty shall not apply to equipment that has been previously repaired or
altered outside our plant in any way which may, in the judgment of the manufacturer,
affect its reliability. Nor will it apply if the equipment has been used in a manner
exceeding or inconsistent with its specifications or if the serial number has been
removed.
CyberResearch, Inc. does not assume any liability for consequential damages 
as a result from our products uses, and in any event our liability shall not exceed 
the original selling price of the equipment.
The equipment warranty shall constitute the sole and exclusive remedy of any Buyer
of Seller equipment and the sole and exclusive liability of the Seller, its successors
or assigns, in connection with equipment purchased and in lieu of all other war-
ranties expressed implied or statutory, including, but not limited to, any implied 
warranty of merchant ability or fitness and all other obligations or liabilities of seller,
its successors or assigns.
The equipment must be returned postage prepaid. Package it securely and insure it.
You will be charged for parts and labor if the warranty period has expired.

Returns and RMAs

If a CyberResearch product has been diagnosed as being non-functional, is visibly
damaged, or must be returned for any other reason, please call for an assigned
RMA number. The RMA number is a key piece of information that lets us track and
process returned merchandise with the fastest possible turnaround time.

PLEASE CALL FOR AN RMA NUMBER!

Packages returned without an RMA number will be refused!

In most cases, a returned package will be refused at the receiving dock if its 
contents are not known. The RMA number allows us to reference the history of
returned products and determine if they are meeting your application’s require-
ments. When you call customer service for your RMA number, you will be asked to
provide information about the product you are returning, your address, and 
a contact person at your organization.

Please make sure that the RMA number is 

prominently displayed on the outside of the box.

• Thank You •

Содержание CYDIO 96P

Страница 1: ...roduced without permission CyberResearch Inc www cyberresearch com 25 Business Park Dr Branford CT 06405 USA 203 483 8815 9am to 5pm EST FAX 203 483 9024 Digital I O CYDIO 96P Multi Channel Digital I...

Страница 2: ......

Страница 3: ...names mentioned herein are used for identification purposes only and may be trademarks and or registered trademarks of their respective companies NOTICE CyberResearch Inc does not authorize any Cyber...

Страница 4: ......

Страница 5: ...Configuration Data 15 5 4 3 Group 2 8255 Configuration Data 14 5 4 2 Group 1 8255 Configuration Data 12 5 4 1 Group 0 8255 Configuration Data 12 5 4 BADR3 11 5 3 BADR2 10 5 2 1 INTCSR Configure 10 5 2...

Страница 6: ...This page is blank...

Страница 7: ...l pull down resistors Provisions have been made on the board to allow users to quickly and easily install SIP resistor networks in either pull up or pull down configurations Figure 1 1 CyDIO 96P Block...

Страница 8: ...This page is blank...

Страница 9: ...re InstaCal is the installation calibration and test software supplied with your data acquisition IO hardware Refer to the Extended Software Installation Manual to install InstaCal If you need it ther...

Страница 10: ...This page is blank...

Страница 11: ...x cable is used to split the 100 I O lines into two 50 wire cables One connector has pins 1 to 50 the other has 51 to 100 The two I O connectors can be connected directly to two screw terminal boards...

Страница 12: ...t A2 A Port A1 A Port A0 A Port B7 A Port B6 A Port B5 A Port B4 A Port B3 A Port B2 A Port B1 A Port B0 A Port C7 A Port C6 A Port C5 A Port C4 A Port C3 A Port C2 A Port C1 A Port C0 A 51 Port A7 D...

Страница 13: ...ble CBL 100xx Configuration 5 SIGNAL CONDITIONING OR 50 PIN SCREW TERMINAL BOARD SIGNAL CONDITIONING or 50 PIN SCREW TERMINAL BOARD CBL 100xx CABLE BOARD S 100 PIN I O CONNECTOR I O PINS 1 TO 50 I O P...

Страница 14: ...Port C0 C 48 49 5V Ground 50 2nd of 2 CBL 100xx 50 Pin Connectors From board pins 51 to 100 1st connector is pin 1 to 1 etc DIO Groups 0 and 1 Pins 51 100 of 100 Pin Conn 51 Port A7 D 52 53 54 55 56...

Страница 15: ...YERB series electromechanical relay output boards CYERB S series 10A electromechanical relay output boards CYSSR series solid state relay I O module racks A description of digital interfacing is in th...

Страница 16: ...96 bits of the CyDIO 96P board may be used to control relays and or SSRs This configuration is shown in Figure 3 4 below The 24 bits of digital I O on CyDIO 96P connector pins 1 24 base address 0 thr...

Страница 17: ...n now to the Universal Library manual 4 2 PACKAGED APPLICATION PROGRAMS Most packaged application programs such as SoftWIRE DAS Wizard and HP VEE have drivers for the CyDIO 96P If the package you own...

Страница 18: ...This page is blank...

Страница 19: ...ace 5 2 BADR1 BADR1 is a 32 bit register for control and configuration of interrupts 5 2 1 INTCSR Configure BADR1 4C hex LEVEL EDGE X INTCLR X ISAMD X X X 8 9 10 11 12 13 14 32 15 READ WRITE INTE INTP...

Страница 20: ...1 interrupt active PCINT PCI interrupt enable 0 disabled default 1 enabled LEVEL EDGE Interrupt trigger control 0 level triggered mode default 1 edge triggered mode INTCLR Interrupt clear edge trigger...

Страница 21: ...ata BADR3 8 Group 1 Configure Group 1 Configure BADR3 7 Group 1 Port C Data Group 1 Port C Data BADR3 6 Group 1 Port B Data Group 1 Port B Data BADR3 5 Group 1 Port A Data Group 1 Port A Data BADR3 4...

Страница 22: ...55 data sheets for information on other modes of operation 8255 MODE 0 CONFIGURATION 1 Output Ports In mode 0 configuration 82C55 ports can be configured as outputs holding the data written to them Fo...

Страница 23: ...OUT OUT 136 88 0 0 1 0 IN OUT IN OUT 131 83 1 1 0 0 OUT OUT IN OUT 130 82 0 1 0 0 IN OUT OUT OUT 129 81 1 0 0 0 OUT OUT OUT OUT 128 80 0 0 0 0 CL CU B A Dec Hex D0 D1 D3 D4 Values Programming Codes No...

Страница 24: ...OUP 2 PORT B DATA BADR3 9 READ WRITE D0 D1 D2 D3 D4 D5 D6 D7 0 1 2 3 4 5 6 7 GROUP 2 PORT C DATA BADR3 A hex READ WRITE CL1 CL2 CL3 CL4 CH1 CH2 CH3 CH4 C1 C2 C3 C4 C5 C6 C7 C8 0 1 2 3 4 5 6 7 GROUP 2...

Страница 25: ...hardware to produce a 32 bit counter for use in interrupt generation This register provides access to the lower 16 data bits Since the interface to the 82C54 is only 8 bits wide write counter data in...

Страница 26: ...et DIRQ0 When this bit is set the 8255 in Group 3 will generate an interrupt on INTRA if INTEN in BASE 15 hex is also set CIRQ1 When this bit is set the 8255 in Group 2 will generate an interrupt on I...

Страница 27: ...es the counters as an interrupt source 1 counters may generate interrupts 0 counters cannot generate interrupts CTR1 Controls whether counter 2 is the interrupt source or counter 1 is the interrupt so...

Страница 28: ...This page is blank...

Страница 29: ...Input High 0 4 volts max 2 5mA Output Low 3 0 volts min 2 5mA Output High 2 banks of 8 and 2 banks of 4 or 3 banks of 8 or 2 banks of 8 with handshake Configuration per 82C55 96 Number of I O Four 82...

Страница 30: ...rrupts are exclusive Only one counter can be enabled as an interrupt source at any given time Interrupt sources Rising falling edge Programmable through PLX 9052 High or low level Programmable through...

Страница 31: ...or reset the control register is set to a known state That state is all ports go to the input state The nature of the input means it will typically float high However depending on the drive requireme...

Страница 32: ...s there are 10 holes in a line One end of the line is 5V the other end is GND They are marked HI and LO respectively The eight holes in the middle are connected to the eight lines of a port 1 through...

Страница 33: ...t Resistance Thus any variation in the voltage drop for the circuit as a whole will have a proportional variation in all the voltage drops in the circuit In a voltage divider the voltage across one of...

Страница 34: ...age must be dropped to 5 volts max when on The Attenuation is 24 5 or 4 8 Use the equation above to find an appropriate R1 if R2 is 1K Remember that a TTL input is on when the input voltage is greater...

Страница 35: ...ormative documents EU EMC Directive 89 336 EEC Essential requirements relating to electromagnetic compatibility EU 55022 Class B Limits and methods of measurements of radio interference characteristic...

Страница 36: ...For Your Notes...

Страница 37: ...a volt meter handy to take measurements of the signals you are trying to measure as well as the signals on the board module or power supply 4 Isolate problem areas that are not working as you expected...

Страница 38: ...in connection with equipment purchased and in lieu of all other war ranties expressed implied or statutory including but not limited to any implied warranty of merchant ability or fitness and all othe...

Страница 39: ......

Отзывы: