CyberResearch COMT 366F Скачать руководство пользователя страница 9

CyberResearch

® 

Serial Communications 

 

COMT 366 Series 

CyberResearch, Inc

.  

1

 

25 Business Park Drive 

 

P: (203) 483-8815; F: (203) 483-9024 

Branford, CT USA 

 

www.cyberresearch.com 

1.0 General Description  

The COMT 366 converter provides a convenient method of interfacing EIA-232-based 
equipment with an RS-485 network using a half-duplex, single twisted-pair transmission 
protocol. The COMT 366 provides the capability for a high-speed, low cost, local area 
network. Up to 32 users can be supported at rates up to 38.4K Baud and total separations 
of 6,000 feet. The LCD feature assists with installation and troubleshooting.  

1.1 The LCD  

Your COMT 366 product incorporates an LCD display designed to provide meaningful 
information to the user. It will assist in the initial installation and check out; thereafter it 
can be used as a performance monitor. In the case of a system problem, it provides 
information as to the status of the local link.  

The logo shown on the LCD display indicates the unit is powered. For power-stealing 
devices such as a converter, it is an indication that sufficient power is being applied to 
operate the device. The LCD display uses less than 1 milliWatt of power.  

The data display on the LCD consists of graphical representations of TD (Transmit Data) 
and RD (Receive Data). Each of these signals is displayed the way a bit-change 
waveform would appear on an oscilloscope. Ordinarily, TD and RD are low or a minus 
voltage in the quiescent state. When data is transmitted, the transmit signal is brought 
high to a positive voltage. These two signal states are displayed on the LCD by either a 
low segment or a high segment. The low segment represents the minus voltage (the mark 
condition) while the upper segment represents a positive voltage (the space condition). 
The vertical bar connecting the lower segment to the upper segment is always on when 
power is applied.  

Содержание COMT 366F

Страница 1: ...eproduced without permission COMT 366 Series RS 232 to RS 485 Converter with LCD 38 4 kbps Data Rate COMT 366M DB 25M Connector COMT 366F DB 25F Connector CyberResearch Inc www cyberresearch com 25 Bu...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...ks CyberResearch and COMT 366 Series are trademarks of CyberResearch Inc Other product names mentioned herein are used for identification purposes only and may be trademarks and or registered trademar...

Страница 6: ...COMT 366 Series CyberResearch Serial Communications iv Copyright 2001 CyberResearch Inc COMT 366 Series...

Страница 7: ...uch interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference If this occurs the user will be required to take whatever m...

Страница 8: ...1 1 1 The LCD 1 2 0 Specifications 3 2 1 Interface 3 2 2 Connectors 3 2 3 Data Rate 3 2 4 Switches 3 2 5 Indicators 3 2 6 Power 3 2 7 Size 3 2 8 Environment 3 3 0 Installation 4 4 0 Operation 5 4 1 T...

Страница 9: ...r In the case of a system problem it provides information as to the status of the local link The logo shown on the LCD display indicates the unit is powered For power stealing devices such as a conver...

Страница 10: ...be displayed simultaneously A variation in display intensity between lower and upper segments will give the user a perception of the amount of data being transmitted The LCD display also shows the sta...

Страница 11: ...inal block 2 3 Data Rate 0 to 38 4 KBPS 2 4 Switches DTE DCE selector switch allows reversing of Pins 2 and 3 of EIA 232 connector Four position dip switch two switches set operating mode two switches...

Страница 12: ...ter will poll the slaves through the single twisted pair and request that only one device access the line at a time The COMT 366 can operate at the following Baud rate distance combinations Baud rate...

Страница 13: ...er The COMT 366 can only transmit data on the RS 485 port if RTS is asserted Note On the COMT 366 only if the RTS signal cannot be controlled then carefully open the covers and locate JP1 and move the...

Страница 14: ...eases the chosen value becomes more critical to error free operation Typically devices at the end of a long bus are terminated and units multi dropped between the ends are not terminated The cable use...

Страница 15: ...e communication parameters set the same On the COMT 366 look at the LCD if RD is shown as a constant high or streaming see Section 1 1 The LCD then the wires are reversed d One of the two wires is bro...

Страница 16: ...ter may now be tested by setting the following switches DCE on COMT 366 DTE Dip Switch 1 ON 2 OFF 3 OFF 4 ON If the converter is functioning correctly any data entered on the keyboard of the terminal...

Страница 17: ...erresearch com 6 0 RS 232 Pin Number Assignments Pin EIA CCITT Name 2 BA 103 Transmit Data 3 BB 104 Receive Data 4 CA 105 Request to Send 5 CB 106 Clear to Send 6 CC 107 Data Set Ready 7 AB 102 Signal...

Страница 18: ...ansformer supplies low voltage AC and the required 12 12 and 5 Volts are generated internally For COMT 366 supply 12 volts on Pin 9 7 1 COMT 366 The COMT 366 is powered by a small wall mounted transfo...

Страница 19: ...mper settings and possibly change settings before reinstalling the modules 3 Have a volt meter handy to take measurements of the signals you are trying to measure as well as the signals on the board m...

Страница 20: ...COMT 366 Series CyberResearch Serial Communications 12 Copyright 2001 CyberResearch Inc Intentionally Blank...

Страница 21: ...pment and the sole and exclusive liability of the Seller its successors or assigns in connection with equipment purchased and in lieu of all other warranties expressed implied or statutory including b...

Страница 22: ...COMT 366 Series CyberResearch Serial Communications 14 Copyright 2001 CyberResearch Inc Intentionally Blank...

Страница 23: ......

Страница 24: ...CyberResearch Inc 25 Business Park Drive Branford CT 06405 USA P 203 483 8815 F 203 483 9024 www cyberresearch com...

Отзывы: