TECHNICAL SPECIFICATIONS 

 

 

 

 

 

 

 

 

 

DEFINITIONS FOR ILLUMINATED LED INDICATORS 

 

 

LED 

 

 

 

Alarm 

Condition 

On 

Off 

Normal 

Flash 

Beep Twice 

Utility Failure - The UPS is providing battery power to outlets. 

Flash 

Rapid Beeping 

Utility Failure - The UPS is providing battery power.    The rapid beeps indicate the battery will run out 

of power shortly. 

On/Flash 

Constant Tone 

Overload - Occurs when connected equipment exceeds the rating of the unit. Turn the UPS off and 

unplug at least one piece of equipment from the UPS.   

 

 

TROUBLESHOOTING 

 

Problem 

Possible Cause 

Solution 

The UPS does not perform 

expected runtime. 

Batteries are not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

Battery is slightly worn out. 

Contact CyberPower Systems Technical Support. 

The UPS will not turn on. 

 

The unit is not connected to an AC outlet. 

The unit must be connected to a 220-240V outlet. 

The battery is worn out. 

Contact CyberPower Systems Technical Support. 

Mechanical problem. 

Contact CyberPower Systems Technical Support. 

Outlets do not provide power to 

equipment 

Fuse is blown or breaker is tripped due to 

overload. 

Turn the UPS off and unplug at least one piece 

connected equipment. Unplug the power cord of the 

UPS then replace the blown fuse with a spare one or 

press the circuit breaker knob. Connect power cord 

then turn the UPS on. Make sure that your spare fuse 

meets the specification. 

Batteries are discharged 

Allow the unit to recharge for at least 4 hours. 

Unit has been damaged by a surge or spike. 

Contact CyberPower Systems Technical Support. 

 

For more information, visit 

www.cyberpower.com

   

All rights reserved. Reproduction without permission is prohibited. 

6F, No. 32, Sec. 1, Chenggong Rd., Nangang District, Taipei 115, Taiwan 

 

 

 

Model 

 

UT1500E

 

UT1500EI

 

UT1500E-AS

 

UT1500E-IN

 

UT2200E

 

UT2200EI

 

UT2200E-AS

 

UT2200E-IN

 

Capacity  (VA) 

1500 

2200 

Watt  (W) 

900 

1320 

Input 

Voltage Range 

165~290Vac 

Nominal Frequency 

50 Hz 

Output 

On Battery Output 

Voltage 

Simulated Sine Wave at /-5% 

On Battery Output 

Frequency   

50 Hz +/-1% 

Overload Protection 

Breaker / Fuse 

Physical

 

Total # of UPS 

Receptacles 

SCHOKO 

6 IEC 

4 ASEAN 

4 INDIA 

SCHOKO 

6 IEC 

4 ASEAN 

4 INDIA 

Dimensions (W x H x 

D)(mm) 

148 X 178 X 298 

Weight (kg) 

9.1 kg 

10.8 kg   

Battery

 

Sealed Maintenance 

Free Lead Acid Battery 

RBP0089 x2 

RBP0090 x2 

Typical Recharge Time 

8 Hours 

Warning Diagnostics 

Indicators 

Power On / Using Battery 

Audible Alarms 

On Battery, Low Battery, Overload, Fault 

Surge Protection

 

Network/ Phone/ Fax/ 

Modem Protection 

YES 

Communication

 

PowerPanel® Personal 

Edition Software 

Windows 8/7/Vista/XP/2000,Server 2012/2008/2003, Linux 

Environmental

 

Operating Temperature 

0

°

C to 40

°

Operating Relative 

Humidity 

0 to 90% 

Management

 

Auto-Charger 

Yes 

Auto-Restart 

Yes 