SE450G1 / SE450B / SX650U / SX950U 

User

’s

 Manual

 

 

K01-0000691-03

 

 

 

Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at: 

www.CyberPowerSystems.com/Registration

. Registration certifies your product's warranty, confirms your ownership 

in the event of a product loss or theft and entitles you to free technical support. Register your product now to receive the 

benefits of CyberPower ownership. 

 

 

 

(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and 

operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 

CAUTION!   

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free 

of conductive contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!   

To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside. 

CAUTION!   

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!   

The

 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into 

an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!   

To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer 

component. 

CAUTION!

    Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data 

Processing Equipment, ANSI/NFPA 75.

 

CAUTION!

    To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over 

current protection in accordance with the National Electric Code, ANSI/NFPA 70. 

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!   

CyberPower Systems does not sell products for life 

support or medical applications. 

DO NOT

 use in any circumstance that would affect operation and safety of life support 

equipment, any medical applications or patient care. 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an 

aquarium.

   

Condensation from the aquarium can cause the unit to short out. 

DO NOT USE THE UPS ON ANY TRANSPORTATION!   

To reduce the risk of fire or electric shock, do not use the unit 

on any transportation such as airplanes or ships.

 

The effect of shock or vibration caused during transit and the damp 

environment can cause the unit to short out. 

 
 

 

 

INTRODUCTION 

Thank you for selecting a CyberPower Systems Uninterruptable Power Supply (UPS). This UPS meets the Energy 

Efficiency Certification of the California Energy Commission (CEC). CyberPower Systems is dedicated to producing 

energy efficient products to maximize our contribution to the environment. 

 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 

(a) UPS unit (b) 

User’s manual (c) USB device cable (except for SE450G1/SE450B) 

*PowerPanel® Personal software is available on our website. Please visi

www.CyberPowerSystems.com

 and 

go to the Software Section for free download. 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

 

1. 

Ensure that the equipment plugged into the UPS does not e

xceed the UPS unit’s rated capacity. If the rated 

capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the 

circuit breaker to trip. 

2. 

There are many factors that can affect the amount of power that your electronic equipment will require.    For 

optimal system performance keep 

the load below 80% of the unit’s rated capacity. 

 

HARDWARE INSTALLATION GUIDE 

1. 

Your new UPS may be used immediately upon receipt. However, after receiving 

a new UPS, to ensure the battery

’s maximum charge capacity, it is 

recommended that you charge the battery for at least 8 hours. Your UPS is 

equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, 

the battery will automatically charge whether the UPS is turned on or turned off. 

2. 

With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals requiring 

battery backup into the battery power supplied outlets. Plug the other peripheral equipment (e.g. printer, scanner, 

speakers, etc.) into the full-time surge protection outlets. 

DO NOT plug a laser printer, paper shredder, copier, 

space heater, vacuum cleaner, sump pump, or other large electrical device into the 

“Battery and Surge 

Protected Outlets

”. The power demands of these devices will overload and possibly damage the unit. 

3. 

Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is 

protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air 

conditioner, refrigerator, copier, etc.). The warranty prohibits the use of extension cords, outlet strips, and surge 

strips in conjunction with the UPS unit.

 

4. 

Press the power switch to turn the unit on. The Power On indicator light will illuminate green and the unit will 
“beep” twice.

 

5. 

If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn 

the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Make sure the 

circuit breaker is depressed and then turn the UPS on.

 

6. 

To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.

 

7. 

To store the UPS for an extended period of time, cover it and store with the battery fully charged. 

While in storage, recharge the battery every three months to ensure optimal battery life.

 

8. 

Ensure the wall outlet and UPS are located near the equipment being attached for proper 

accessibility.

 

9. 

Lay the UPS horizontally or use the key-hole mounting slots to affix the UPS to the 

wall in the proper orientation. DO NOT stand the UPS up vertically.

 

 
DESCRIPTION 

 

 

 

 

 

 

 

 

1. 

Power Switch 

To turn the UPS on, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - 

and release after a short beep. 

To turn the UPS off, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) 

- and release after two short beeps. 

Alarm setting: The audible alarm can be turned OFF or ON by quickly pressing the POWER button twice. The 

default setting is for the Alarm On. To turn the Alarm Off, quickly press the power button twice. You will hear two 

short beeps when the Alarm is turned Off. To turn the Alarm back ON, quickly press the power button twice. You 

will hear a single short beep when the Alarm is turned On.   

*When the Alarm is turned Off, there will be no audible notification when the UPS reaches a low battery state.

 

2. 

Power On Indicator 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges 

and spikes.

 

3. 

Battery and Surge Protected Outlets 

The unit has several battery powered and surge protected outlets to ensure temporary uninterrupted operation of 

your equipment during a power failure. 

(DO NOT plug a laser printer, paper shredder, copier, space heater, 

vacuum cleaner, sump 

pump, or other large electrical device into the “Battery and Surge Protected 

Outlets.” The power demands of these devices will overload and possibly damage the unit.) 

4. 

Full-Time Surge Protection Outlets 

The unit has several surge suppression outlets.

 

5. 

Circuit Breaker 

Located on the side of the UPS, the circuit breaker provides overload and fault protection.

 

6. 

USB Port to PC (except for SE450G1/SE450B) 

The port allows connection and communication between the USB port on the computer and the UPS unit. The UPS 

communicates its status to the PowerPanel

®

 Personal software.

 

7. 

USB Charging ports (except for SE450G1/SE450B) 

The USB charging ports provide 5V 2.4A power output. 

8. 

Outlets Designed for AC Adapters 

The UPS unit has four widely-spaced outlets, so AC power adapters can be plugged into the UPS without 

overlapping or blocking adjacent outlets. 

 

 

 
 
 

Problem

 

Possible Cause 

Solution

 

Full-time surge protection outlets 

stop providing power to 

equipment. Circuit breaker 

button is projecting from the side 

of the unit.

 

Circuit breaker has been 

tripped due to an overload. 

Turn the UPS off and unplug at least one 

piece of equipment. Wait 10 seconds, reset 

the circuit breaker by pressing the button, 

and then turn the UPS on.

 

The UPS does not perform 

expected runtime. 

Battery not fully charged. 

Recharge the battery by leaving the UPS 

plugged in. 

Battery is worn out. 

Contact CyberPower Systems about 

replacement batteries. 

The UPS will not turn on. 

The on/off switch is designed 

to prevent damage from 

rapidly turning it off and on. 

Turn the UPS off. Wait 10 seconds and then 

turn the UPS on. 

The unit is not connected to an 

AC outlet. 

The unit must be connected to a 110/120V 

50/60Hz outlet. 

The battery is worn out. 

Contact CyberPower Systems about 

replacement batteries. 

Mechanical problem. 

Contact CyberPower Systems.   

The frequency is outside of the 

operating range of 47-63Hz.. 

Turn the UPS off. Make sure the frequency 

range is within 47-63Hz. Or you can turn the 

UPS on in battery mode. 

PowerPanel

®

 Personal is 

inactive (all icons are gray). 

*except for SE450G1/SE450B 

The USB cable is not 

connected. 

Connect the USB cable to the UPS unit and 

an open USB port on the back of the 

computer. 

The USB cable is connected to 

a bad USB port. 

Check for a different USB port and plug the 

cable in. 

The unit is not providing 

battery power. 

Shutdown your computer and turn the UPS 

off. Wait 10 seconds and turn the UPS back 

on. This should reset the unit. 

 

Additional troubleshooting information can be found at 

“Support” at 

www.CyberPowerSystems.com

 

 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

TROUBLESHOOTING 

IMPORTANT SAFETY WARNINGS 