CyberPower OL10KRT2UTFHWIORTAA Скачать руководство пользователя страница 2

 

Copyright ©  2014 CyberPower Systems, Inc.

 

OVERVIEW 

1

 

 

The  CyberPower  Step-Down  and  Isolation  Transformers  support  installation  with  hardwire  (OL6KRT2UTFHWIOTAA  /  OL10KRT2UTFHWIOTAA  / 
OL6KRT2UTFHWIORTAA / OL10KRT2UTFHWIORTAA), and are designed for a variety of CyberPower UPS systems. When combined with the UPS, the 
Step-Down configuration converts voltage from 200-240V down to 100-120V. The Isolation configuration provides the UPS and connected equipment from 
any outside utility line fluctuations or interference. 

 
 

 

2U Step-Down and Isolation Transformer

 

                             

 

User’s manual                    Registration card 

 

Rackmount left rail          Rackmount right rail 

 

Tie plate (1) * 1 set 

 

2U Rackmount ears (Stands) (2) * 1 set 

 

 

Input/output terminal block cover (1) 

 

Flat head screws

:

 M5X8L (8) * 1 set 

 

Pan head screws

:

 M5X12L (12) * 1 set   

 

Plastic washers (8) * 1 set   

 

Screw hole dust covers (10) * 1 set 

 

Cable for 6K UPS output to 6K STF input connection (1) 

(Only for 6K STF) 

 

Conduits with internal wires for 8K/10K UPS output to 

10K STF input connection (1) 

(Only for 10K STF) 

 

Cable glands (2)

 

 

UNPACKING 

Содержание OL10KRT2UTFHWIORTAA

Страница 1: ...Down Transformer OL6KRT2UTFHWIOTAA OL10KRT2UTFHWIOTAA OL6KRT2UTFHWIORTAA OL10KRT2UTFHWIORTAA CyberPower Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 Phone 877 297 6937 Fax 952 403...

Страница 2: ...des the UPS and connected equipment from any outside utility line fluctuations or interference 2U Step Down and Isolation Transformer User s manual Registration card Rackmount left rail Rackmount righ...

Страница 3: ...hes deep Select the proper holes in the rack for positioning the Step Down Transformer in the rack The 2U Step Down Transformer takes up position 1 through position 6 The 3U Step Down Transformer take...

Страница 4: ...odule Step 3 Attach dust covers Insert dust covers into the rackmount ear screw holes that are not being used SAFETY PRECAUTIONS CAUTION Installation environment should be in a temperature and humidit...

Страница 5: ...eck wiring dimensions with the following table Step Down and Isolation Transformers with hardwire Wiring AWG Wiring mm 2 OL6KRT2UTFHWIOTAA OL6KRT2UTFHWIORTAA 10 AWG 5 5 mm 2 OL10KRT2UTFHWIOTAA OL10KRT...

Страница 6: ...iguration Insert the input output cables through the appropriate cable gland Hardwire the input output terminals as shown in the following terminal block identification and configuration table Step 4...

Страница 7: ...Voltage L1 L2 200Vac L1 N L2 100Vac 0 100Vac L1 L2 200Vac L1 L2 220Vac L1 N L2 110Vac 0 110Vac L1 L2 220Vac L1 L2 230Vac L1 N L2 115Vac 0 115Vac L1 L2 230Vac Input Voltage AC Output Connection Output...

Страница 8: ...pyright 2014 CyberPower Systems Inc HARDWIRING THE INPUT OUTPUT TERMINALS 7 POWER CABLE CONNECTION OL6000RT3UTFTAA OL6000RT3UPDUTFTAA OL8000RT3UTFTAA OL10000RT3UTFTAA OL8000RT3UPDUTF OL10000RT3UPDUTFT...

Страница 9: ...output terminal block 3 Battery Backup Surge Protected Outlets 120Vac Provides battery backup and surge protection They ensure power is provided to connected equipment over a period of time during a p...

Страница 10: ...OL6KRT2UTFHWIOR TAA OL6KRT2UTFHWIO TAA OL10KRT2UTFHWIOR TAA OL10KRT2UTFHWIO TAA Configuration Maximum Output Power VA 6000VA 10000VA Maximum Output Power W 6000W 10000W Form Factor Rackmount Tower In...

Страница 11: ...ber the Purchase Date and each item of Connected Equipment 2 Email us at tech cpsww com or Call us at 877 297 6937 3 If your product requires warranty service you must provide a copy of your dated pur...

Страница 12: ...1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on pro...

Страница 13: ...interference in which case the user will be required to correct the interference at his own expense Shielded signal cables must be used with this product to ensure compliance with the Class A FCC lim...

Отзывы: