DEFINITIONS FOR ILLUMINATED LCD INDICATORS

TROUBLESHOOTING

TECHNICAL SPECIFICATIONS

1  . ONLINE: 

The UPS is supplying utility power to connected equipment.

2  . ENERGY-SAVING:

 The UPS in energy-saving bypass mode. See “CyberPower 

GreenPower UPS™ Technology” section for more information.

3  . AVR (Automatic Voltage Regulation): 

This icon appears whenever your UPS is 

automatically correcting low AC line voltage without using battery power. This is a 
normal, automatic operation of your UPS, and no action is required on your part.

4  . ON BATTERY: 

During a loss in power or severe sag, this icon appears and an alarm 

sounds (two short beeps followed by a pause) to indicate the UPS is operating from its 
internal batteries.  During a prolonged loss in power, the alarm will beep rapidly every 
1/2 second to indicate the UPS’s batteries are nearly out of power. You should save 
files and turn off your equipment immediately or allow the software to shut the system 
down.

5  . BATTERY CAPACITY: 

This meter displays the approximate charge level (in 20% 

increments) of the UPS’s internal battery. During a loss in power or severe sag the UPS 
switches to battery power, the BATTERY icon appears, and the charge level decreases.

6  . REPLACE BATTERY: 

This icon illuminates when the batteries are not connected well 

or the batteries were worn out.

7 . FAULT: 

This icon appears if there is a problem with the UPS. Press the POWER button 

to turn the UPS off.

E01 : 

Charger Fault – Overcharge (Contact CyberPower Systems for support.)

E02 : 

Charger Fault – No Charge (Contact CyberPower Systems for support.)

E11 : 

Battery Overvoltage (Contact CyberPower Systems for support.)

E21 : 

Output Short (Check the status of equipment connected to the UPS and then 

turn on the UPS again.)

E22 : 

Overload (Unplug at least one piece of equipment from battery outlets and turn 

the UPS on again.)

8 . OVERLOAD:

 This icon appears and an alarm sounds to indicate the battery-supplied 

outlets are overloaded. To clear the overload, unplug one piece of equipment from the 
battery-supplied outlets at a time until the icon turns off and the alarm stops.

9 .  CURRENT LOAD:

 This meter displays the approximate output load level (in 20% 

increments) of the UPS battery outlets.

10

 

. SCHEDULE: 

Users can setup the schedule to turn on and shut down the computer and 

UPS through PowerPanel® Personal software. The LCD display will show how much 
time is left before the UPS will turn back on or shut down.

11 . MUTE: 

This icon appears whenever the UPS is in silent mode. However, when there is a 

problem with the UPS, the alarm will still beep even in silent mode.

12 .  SENSITIVITY  SETUP: 

This meter is also used to setup the UPS sensitivity when you 

are in the programming mode. If the connected equipment can tolerate more power 
events (example: unstable power often associated with stormy weather), select Low 
Sensitivity and the UPS will go to Battery Mode less often. If the connected equipment 
is more sensitive to power events, select High Sensitivity and the UPS will go to 
Battery Mode more often.

13 .  ESTIMATED  RUNTIME: 

This displays the runtime estimate of the UPS with current 

battery capacity and load.

14 .  OUTPUT  METER: 

This meter measure, in real time, the AC voltage that the UPS system 

is providing to the computer, such as normal AC line mode, AVR mode, and battery 
backup mode. (Note: The OUTPUT meter shows the status of the battery backup 
outlets in terms of load, frequency, and voltage.)

15 .  EVENT: 

This meter records the number of power outages.

16 .  INPUT  METER: 

This meter measures the AC voltage that the UPS system is receiving 

from the utility wall outlet. The INPUT voltage meter can be used as a diagnostic tool 
to identify poor-quality input power.

For more information about functions setup, please refer to the Function Setup Guide.

Problem

Possible Cause

Solution

Circuit breaker button is projecting from the back of 
the unit.

Circuit breaker has tripped due to an overload.

Turn the UPS off and unplug at least one piece of equipment. 
Wait 10 seconds, reset the circuit breaker by depressing the 
button, and then turn the UPS on.

The UPS does not perform expected runtime.

Battery not fully charged.

Recharge the battery by leaving the UPS plugged in.

Battery is worn out.

Contact CyberPower about replacement batteries.

The UPS will not turn on.

The on/off switch is designed to prevent damage from 
rapidly turning it off and on.

Turn the UPS off. Wait 10 seconds and then turn the UPS on.

The unit is not connected to an AC outlet.

The unit must be connected to a 110/120V 60Hz outlet.

The battery is worn out.

Contact CyberPower about replacement batteries.

Mechanical problem.

Contact CyberPower.

PowerPanel® Personal software is inactive  
(all icons are gray).

The USB / serial cable is not connected.

Connect the USB / serial cable to the UPS unit and an open USB 
/ serial port on the back of the computer.

The USB / serial cable is connected to the wrong port.

Check the back of the computer for an additional USB / serial 
port. Move the cable to this port.

The unit is not providing battery power.

Shutdown your computer and turn the UPS off. Wait 10 seconds 
and turn the UPS back on. This should reset the unit.

The USB charging ports are not providing power to the 
connected devices.

The USB power port has Over Current Protection design. 
When the total current of connected devices is over 4 A, 
the USB charging ports will stop providing power to the 
connected devices.

Turn the UPS off and unplug at least one piece of device 
connected to the USB charging port and then turn the UPS on.

Additional troubleshooting information can be found under “Support” at www.CyberPowerSystems.com.

Model

LX1100G3

-FC

LX1325GU3

-FC

LX1500GU3

-FC

Capacity

1100VA / 660W

1325VA / 810W

1500VA / 900W

Nominal Input Voltage

120V

Input Frequency

60 Hz ± 3 Hz

On-Battery Output Voltage

120Vac ± 5%

Max. Load for UPS Outlets (5 Outlets)

1100VA / 660W

1325VA / 810W

1500VA / 900W

Max. Load for Full-Time Surge Protection 
outlets (10 Outlets)

12 Amp

On-Battery Output Wave Form

Simulated Sine Wave

Operating Temperature

+ 32°F to 104° F / 0° C to 40° C

Operating Relative Humidity

0 to 90% non-condensing

Size (W x H x D)

3.9" x 9.8" x 13.7" (99 x 249 x 348 mm)

Net Weight

21.8lbs / 9.9kg

22.2lbs / 10.1kg

25lbs / 11.3kg

Battery Type

CyberPower / RB1270X2C

CyberPower / RB1270X2C

CyberPower / RB1290X2

Typical Battery Recharge Time

8 hours to 90% capacity from total discharge

Typical Battery Life

3 to 6 years, depending on number of discharge/recharge cycles

Recommended Battery

Sealed Maintenance Free Lead Acid Battery

Safety Approvals

UL1778 (UPS), CSA C22.2 No. 107, FCC/DoC Class B

SYSTEM BLOCK DIAGRAM

Input

Output

EMI Fllter

Surge

Suppressor

AVR

Charger

AC / DC

Battery

Inverter

Normal Mode
Battery Mode

This device complies with part 15 of the FCC rules. Operation is subject to the 
following two conditions: (1) this device may not cause harmful interference, 
and (2) this device must accept any interference received, including 
interference that may cause undesired operation.

Note: 

This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the user 
is encouraged to try to correct the interference by one or more of the following measures:

FCC COMPLIANCE STATEMENT

- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is 

connected.

- Consult the dealer or an experienced radio/TV technician for help.

Important: Changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate the equipment.

Canadian Compliance Statement 

CAN ICES-3 (B)/NMB-3(B)

FCC COMPLIANCE STATEMENT - Continued 

CYBERPOWER GREENPOWER UPS™ TECHNOLOGY

Advanced Energy-Saving Patented Bypass Technology

CyberPower’s patented GreenPower UPS™ with Bypass Technology 
reduces UPS energy costs by up to 75% compared to conventional UPS 
models. Even when utility power is normal, conventional UPS models 
constantly pass power through a transformer. By contrast, under normal 
conditions the advanced circuitry of a GreenPower UPS™ bypasses the 
transformer. As a result, the power efficiency is significantly increased 
while decreasing waste heat, using less energy, and reducing energy costs.
When an abnormal power condition occurs, the GreenPower UPS™ automatically runs power 
through its transformer to regulate voltage and provide “safe” power. Since utility power is 
normal over 88% of the time, the GreenPower UPS™ operates primarily in its efficient bypass 
mode.

The GreenPower UPS™ is also manufactured in accordance with the Restriction on 
Hazardous Substances (RoHS) directive making it one of the most environmentally-friendly 
on the market today.

G

REEN

P

OWER 

UPS

Energy-Saving Technology

LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE

Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and 
Connected Equipment Guarantee.

Where Can I Get More Information?

The application of the United Nations Convention of Contracts for the International Sale of 
Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty.

For further information please feel free to contact CyberPower at:
Cyber Power Systems (USA), Inc.
4241 12th Ave E., STE 400, Shakopee, MN 55379;
Call us at 

(877) 297-6937

; or 

submit a web ticket online at

 cyberpowersystems.com/support.

WARNING:

 This product can expose you to chemicals including bisphenol A (BPA) and 

styrene, which is known to the State of California to cause reproductive harm and cancer. 
For more information, go to www.P65Warnings.ca.gov.

CyberPowerSystems.com

© 2021 Cyber Power Systems (USA), Inc. PowerPanel® Personal is a trademark of Cyber 
Power Systems (USA) Inc.

All rights reserved. All other trademarks are the property of their respective owners.

DISPLAY

3

7

11

10

12
13
14

15

16

1

9

8

4

5

6

2

Содержание LX1100G3-FC

Страница 1: ...hernet connection 11 Coax Cable DSS Surge Protection The Coax Cable DSS protection ports will protect any cable modem CATV converter or DSS receiver 12 Wiring Fault Indicator red This LED indicator will illuminate to warn the user that a wiring problem exists such as bad ground missing ground or reversed wiring If this is illuminated disconnect all electrical equipment from the outlet and have an ...

Страница 2: ...set the unit The USB charging ports are not providing power to the connected devices The USB power port has Over Current Protection design When the total current of connected devices is over 4 A the USB charging ports will stop providing power to the connected devices Turn the UPS off and unplug at least one piece of device connected to the USB charging port and then turn the UPS on Additional tro...

Страница 3: ...ectionnels offrent une protection contre les surtensions à une connexion Ethernet 10 100 1000 11 Protection contre les surtensions coaxiale câble DSS Les ports de protection Coax Cable DSS protégeront tout modem câble convertisseur CATV ou récepteur DSS 12 Indicateur de défaut de câblage rouge Cet indicateur LED s allume pour avertir l utilisateur qu un problème de câblage existe tel qu une mauvai...

Страница 4: ...initialiser l appareil Les ports de chargement USB n alimentent pas les appareils connectés Le port USB est conçu avec une protection contre les surintensités Lorsque le courant total des appareils connectés dépasse 4 A les ports de chargement USB cessent d alimenter les appareils connectés Éteignez l onduleur et débranchez au moins un appareil connecté au port de chargement USB puis allumez l ond...

Отзывы: