USER MANUAL

Cyber Power Systems (USA), Inc.

4241 12th Avenue East, Suite 400 | Shakopee, MN 55379 | CyberPowerSystems.com

IMPORTANT SAFETY WARNINGS 

(SAVE THESE INSTRUCTIONS)

This manual contains important safety instructions. Please read and follow all instructions 
carefully during installation and operation of the unit. Read this manual thoroughly before 
attempting to unpack, install, or operate your UPS.

CAUTION! 

To prevent the risk of fire or 

electric shock, install in a temperature 
and humidity controlled indoor area free 
of conductive contaminants.  (Please see 
specifications for acceptable temperature 
and humidity range).

CAUTION! 

To reduce the risk of electric 

shock, do not remove the cover except to 
service the battery. Turn off and unplug the 
unit before servicing the batteries. There 
are no user serviceable parts inside except 
for the battery.

CAUTION! 

Hazardous live parts inside can 

be energized by the battery even when the 
AC input power is disconnected.

CAUTION! 

The UPS must be connected 

to an AC power outlet with fuse or circuit 
breaker protection.  Do not plug into an 
outlet that is not grounded.  If you need to 
de-energize this equipment, turn off and 
unplug the unit.

CAUTION! 

To avoid electric shock, turn off 

the unit and unplug it from the AC power 
source before servicing the battery or 
installing a computer component.

CAUTION! 

Not for use in a computer 

room as defined in the Standard for the 
Protection of Electronic Computer/Data 
Processing Equipment, ANSI/NFPA 75.

CAUTION! 

To reduce the risk of fire, 

connect only to a circuit provided with 
20 amperes maximum branch circuit over 
current protection in accordance with the 
National Electric Code, ANSI/NFPA 70.

CAUTION! DO NOT USE FOR MEDICAL 
OR LIFE SUPPORT EQUIPMENT! 

 DO NOT 

use in any circumstance that would affect 
the operation and safety of life support 
equipment, medical applications, or patient 
care.

CAUTION! DO NOT USE WITH OR NEAR 
AQUARIUMS!

  To reduce the risk of fire 

or electric shock, do not use with or near 
an aquarium.  Condensation from the 
aquarium can cause the unit to short out.

CAUTION! DO NOT USE THE UPS ON ANY 
TRANSPORTATION!

  To reduce the risk of 

fire or electric shock, do not use the unit 
on any transportation such as airplanes 
or ships. The effect of shock or vibration 
caused during transit and the damp 
environment can cause the unit to short out.

INSTALLING YOUR UPS SYSTEM

UNPACKING

Inspect the UPS upon receipt. The box 
should contain the following:

(a) UPS unit
(b) User’s manual
(c) USB A+B type cable
(d) Function Setup Guide

*PowerPanel® Personal software is 
available on our website. Please visit 
www.CyberPowerSystems.com and go to 
the Software Section for free download.

OVERVIEW

The LX1100G3

-FC

/LX1325GU3

-FC

/

LX1500GU3

-FC

 provides complete power 

protection from utility power that is not 
always consistent. The 

LX1100G3-FC/

LX1325GU3-FC/LX1500GU3-FC 

features 

890 Joules of surge protection. The unit 
provides long lasting battery backup 
during power outages with maintenance 
free batteries. The 

LX1100G3-FC/

LX1325GU3-FC/LX1500GU3-FC 

ensures 

consistent power to your computer system 
and includes software that will 
automatically save your open files and 
shutdown your computer system during a 
utility power loss.

AUTOMATIC VOLTAGE REGULATOR

The 

LX1100G3-FC/LX1325GU3-FC/

LX1500GU3-FC

 uses Automatic Voltage 

Regulation (AVR) to stabilize inconsistent 
utility power voltage to levels that are safe 
for connected equipment. AVR safeguards 
hardware and important data files by 
automatically increasing low utility power 
to a consistent and safe output voltage 
while preserving battery power for 
outages. 

DETERMINE THE POWER 
REQUIREMENTS OF YOUR EQUIPMENT

1  . Ensure that the equipment plugged 

into the outlet does not exceed the 
UPS’s rated capacity (1100VA/660W 
for LX1100G3

-FC

, 1325VA/810W for 

LX1325GU3

-FC

, 1500VA/900W for 

LX1500GU3

-FC

).  If the rated capacity 

of the unit is exceeded, an overload 
condition may occur and cause the 
UPS to shut down or the circuit breaker 
to trip. 

2  . There are many factors that can 

affect the amount of power that your 
computer system will require.  It is 
suggested that the load placed on the 
battery outlets not exceed 80% of the 
unit’s capacity.

1  . Power Switch: 

Used as the master on/

off switch for equipment connected to 
the battery power supplied outlets.

2  . Power On Indicator:

 This LED is 

illuminated when the utility power 
is normal and the UPS outlets are 
providing power, free of surges and 
spikes. 

3  . LCD module display: 

High resolution 

and intelligent LCD display shows all 
the UPS information using icons and 
messages.  For more information please 
review the “Definitions for Illuminated 
LCD Indicators” section below.

4  . Display/Select button:

 The button 

can be used to select the LCD display 
contents including Input Voltage, 
Output Voltage, and Estimated Run 
Time. Short press the button to scroll 
down the function menu. Pressing the 
button for 3 seconds will keep the 
LCD display always on or turn the LCD 
display off while in AC/Utility power 
mode. For more information about the 
Down/Display Button, please refer to 
the Function Setup Guide.

5  . USB Charging Ports (Except for 

LX1100G3

-FC

): 

The USB charging 

ports provide 5Vdc, 3A Max (USB-C), 
and 5 Vdc., 2.4A Max (USB-A). Total 
Output Current: 4A

6  . Battery and Surge Protected 

Outlets: 

The unit has 5 battery 

powered/surge suppression outlets 
for connected equipment to ensure 
temporary uninterrupted operation 
of your equipment during a power 
failure. (DO NOT plug a laser printer, 
paper shredder, copier, space heater, 
vacuum, sump pump or other large 
electrical devices into the “Battery 
and Surge Protected Outlets”. The 
power demands of these devices may 
overload and damage the unit.)

7  . Full-Time Surge Protected Outlets: 

The 

unit has 5 surge suppression outlets.

8  . Circuit Breaker:

 Located on the back 

of the UPS, the circuit breaker serves to 
provide overload and fault protection. 

9  . USB Ports to PC: 

The USB port 

allowsconnection and communication 
between the USB port on the computer 
and the UPS unit.

10 . Communication Protection Ports 

(RJ45): 

Bi-directional communication 

ports provide surge protection to a 
10/100/1000 Ethernet connection.

11 . Coax/Cable/DSS Surge Protection: 

The Coax/Cable/DSS protection ports 
will protect any cable modem, CATV 
converter, or DSS receiver.

12 . Wiring Fault Indicator (red): 

This 

LED indicator will illuminate to warn 
the user that a wiring problem exists, 
such as bad ground, missing ground or 
reversed wiring.  If this is illuminated, 
disconnect all electrical equipment 
from the outlet and have an electrician 
verify the outlet is properly wired. The 
unit will not provide surge protection 
without being plugged into a grounded 
and properly wired wall outlet.

13 . Widely Spaced Outlets Designed for 

AC Adapters:

 The unit has 2 outlets 

spaced to allow AC power adapter 
blocks to be plugged into the UPS 
without blocking adjacent outlets.

BASIC OPERATION

Replacement of batteries located in an 

OPERATOR ACCESS AREA

.  

1  . When replacing batteries, replace with the same number of the following battery: 

CyberPower / RB1270X2C for the LX1100G3

-FC

/LX1325GU3

-FC

, and CyberPower / 

RB1290X2 for the LX1500GU3

-FC

.

2 . 

CAUTION!  

Risk of Energy Hazard, 24 V, maximum 9 Ampere-hour battery. Before 

replacing batteries, remove conductive jewelry such as chains, wrist watches, and 
rings. High energy conducted through these materials could cause severe burns.

3 . 

CAUTION!  

Do not dispose of batteries in a fire. The batteries may explode.

4 . 

CAUTION!  

Do not open or mutilate batteries. Released material is harmful to the skin 

and eyes. It may be toxic.

5 . 

CAUTION:  

A battery can present a risk of electrical shock and high short circuit 

current. The following precautions should be observed when working on batteries:

1) Remove watches rings, or other metal objects.
2) Use tools with insulated handles.

CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. 
DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS.

REPLACING THE BATTERY

BATTERY REPLACEMENT PROCEDURE:

1  . Switch off and unplug all the connected equipment.
2  . Switch off the UPS and disconnect it from the wall outlet.
3  . Place the product on its side, on a solid and stable surface.
4  . Loosen the battery compartment cover screws.
5  . Press on the locking latch and slide the battery compartment cover.
6  . Disconnect the battery wires from the right side of the battery and then take it out of 

the battery compartment.

7  . Disconnect the battery wires from the remaining battery. 
8  . Slide the remaining battery from left to right and remove it from the compartment.  
9  . Install the "left side" replacement battery by connecting the yellow wire (+) to the red 

connector from the battery and the black wire (-) to the black connector from the 
battery. Place the battery into the left side of the compartment.

10  . Install the "right side" replacement battery by connecting the red wire (+) to the 

red connector from the battery and yellow wire (-) to the black connector from the 
battery. Place the battery into the right side of the compartment. Note: Only new 
batteries should be used for replacement and both batteries should be replaced at 
the same time to ensure maximum life span.

1 1  . Close the battery compartment cover and secure it with the screws.
1 2 . Recharge the UPS for 8-16 hours to fully charge the battery.

REMINDER: 

 Batteries are considered HAZARDOUS WASTE and must be disposed of properly.  Most retailers that sell lead-acid batteries collect used batteries for recycling, as required by 

local regulations.

K01-0000954-00

HARDWARE INSTALLATION GUIDE

1  . Your new UPS may be used 

immediately upon receipt. However, 
after receiving a new UPS, to ensure 
the battery’s maximum charge capacity, 
it is recommended that you charge the 
battery for at least 8 hours. Your UPS is 
equipped with an auto-charge feature. 
When the UPS is plugged into an AC 
outlet, the battery will automatically 
charge whether the UPS is turned on or 
off. 

Note: 

This UPS is designed with a 

safety feature to keep the system from 
being turned on during shipment. The 
first time you turn the UPS on, you will 
need to have it connected to AC power 
or it will not power up.

2  . With the UPS 

unit turned off 
and unplugged, 
connect your 
computer, monitor, 
and any other peripherals requiring 
battery backup into the battery power 
supplied outlets. 

DO NOT plug a 

laser printer, paper shredder, copier, 
space heater, vacuum, sump pump 
or other large electrical devices into 
the “Battery and Surge Protected 
Outlets”. The power demands of these 
devices may overload and damage the 
unit.

3  . Plug the UPS into a 2 pole, 3 wire 

grounded receptacle (wall outlet). 
Make sure the wall branch outlet is 
protected by a fuse or circuit breaker 
and does not service equipment with 
large electrical demands (e.g. air 
conditioner, copier, etc

.

). The warranty 

prohibits the use of extension cords, 
outlet strips, and surge strips. 

4  . Press the power switch to turn the 

unit on. The Power On indicator light 
will illuminate and the unit will “beep”. 
If an overload is detected, an audible 
alarm will sound and the unit will emit 
one long beep. To correct this, turn the 
UPS off and unplug at least one piece 
of equipment from the battery power 
supplied outlets. Make sure the circuit 
breaker is depressed and then turn the 
UPS on.

5  . To maintain optimal battery charge, 

leave the UPS plugged into an AC 
outlet at all times.

6  . To store the UPS for an extended 

period, cover it and store with the 
battery fully charged.  While in storage, 
recharge the battery every three 
months to ensure battery life.

7  . Ensure the wall outlet and UPS are 

located near the equipment being 
attached for proper accessibility.

INSTALLING YOUR UPS SYSTEM - Continued 

PLUG IN

1

2

3

4

5

6

7

8

(+)Red

(-)Black

(-)Black

(+)Red

PRODUCT REGISTRATION

Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at www.cyberpowersystems.com/registration/. Registration certifies your product's 
warranty, confirms your ownership in the event of a product loss or theft and entitles you to free technical support. Register your product now to receive the benefits of CyberPower ownership.

FEATURES

1  . Power Switch
2 . Power On Indicator
3 . LCD module display
4 . Display/Select button
5 . USB Charging Ports (Except for LX1100G3

-FC

)

 

6 . Battery and Surge Protected Outlets
7 . Full-Time Surge Protected Outlets
8 . Circuit Breaker
9 . USB Ports to PC

10 . Communication Protection Ports (RJ45)
1 1 . Coax/Cable/DSS Surge Protection
12 . Wiring Fault Indicator (red)
13 . Widely Spaced Outlets Designed for AC Adapters

1500

3

1

4

5

2

9

11

12

8

7

10

13

13

6

Содержание LX1100G3-FC

Страница 1: ...hernet connection 11 Coax Cable DSS Surge Protection The Coax Cable DSS protection ports will protect any cable modem CATV converter or DSS receiver 12 Wiring Fault Indicator red This LED indicator will illuminate to warn the user that a wiring problem exists such as bad ground missing ground or reversed wiring If this is illuminated disconnect all electrical equipment from the outlet and have an ...

Страница 2: ...set the unit The USB charging ports are not providing power to the connected devices The USB power port has Over Current Protection design When the total current of connected devices is over 4 A the USB charging ports will stop providing power to the connected devices Turn the UPS off and unplug at least one piece of device connected to the USB charging port and then turn the UPS on Additional tro...

Страница 3: ...ectionnels offrent une protection contre les surtensions à une connexion Ethernet 10 100 1000 11 Protection contre les surtensions coaxiale câble DSS Les ports de protection Coax Cable DSS protégeront tout modem câble convertisseur CATV ou récepteur DSS 12 Indicateur de défaut de câblage rouge Cet indicateur LED s allume pour avertir l utilisateur qu un problème de câblage existe tel qu une mauvai...

Страница 4: ...initialiser l appareil Les ports de chargement USB n alimentent pas les appareils connectés Le port USB est conçu avec une protection contre les surintensités Lorsque le courant total des appareils connectés dépasse 4 A les ports de chargement USB cessent d alimenter les appareils connectés Éteignez l onduleur et débranchez au moins un appareil connecté au port de chargement USB puis allumez l ond...

Отзывы: