POWERPANEL PLUS™ SOFTWARE USER MANUAL 

 

OVERVIEW 
 

PowerPanel Plus™ version 1.13 or greater is designed for use with Windows 95, Windows 98, Windows Me, Windows NT and Windows 2000.  The latest 
version can be downloaded from 

www.cyberpowersystems.com/downloads.htm

.  It works in conjunction with the UPS to provide full protection of valuable 

computer systems, applications and data.  In the event of a power failure, PowerPanel Plus™ automatically saves and closes open files under auto-
assigned file names or existing files names after a software controlled delay.  The computer and UPS are automatically shutdown to conserve battery power.  
Files with auto-assigned names will be saved under 

C:\PCTemp

, where 

C

 is the name of your main hard drive.  Files that have previously been saved will 

be saved in their original location. 

 

PowerPanel Plus™ is equipped with a 

Schedule 

feature that can automatically save and close open files and then shutdown the computer and UPS at a 

user specified date and time as well as start the computer at a user specified date and time.  Use of this feature is optional and is not required for the power 
failure shutdown to occur. 
 

The use of the PowerPanel Plus™ software is optional

.  The UPS unit will provide full surge suppression and battery backup without the software.  You 

must use the software if you wish to have the automatic shutdown feature. 

 
POWERPANEL PLUS™ MAIN  MENU 
 

 

1. Log 

Button

:  Click on the log button to open the 

Log Window

2. Power 

Button:

  Clicking on the power button will stop the software. 

3. Minimize 

Button: 

 

Click this button to minimize the software. 

4. Setup 

Button:

  Click the setup button to open the 

Setup Window

5. Model:

  This shows the model of the CyberPower UPS that is being used. 

6. Version: 

 

This shows the 

hardware version

7. 

Status Bar:  

The area display messages about the status of the software. 

8. Schedule 

Button:

  Click this button to access the 

Schedule Window

 

 

POWERPANEL PLUS™ MAIN WINDOW DESCRIPTION 
 

 

 

1. 

Input Voltage:  

This reading shows the current input voltage of the utility power.  The input normally appears in green, but will turn red if the input 

voltage is lower than 85v or higher than 150v. 

2. 

Battery Level:  

This indicator displays the current charge on the battery.  The indicator will display a red color when a power failure occurs. 

3. Frequency:

  This indicator displays the frequency of the utility power. 

4. Scheduled 

On:

  PowerPanel Plus™ can be scheduled to turn your computer system on.  It can only be set when a 

Scheduled Off

 is also set.  

Scheduled On

 settings that are set to occur within seven days will be displayed.   When the UPS is in standby, after the 

Scheduled Off

, the using 

battery and check battery indicators will flash in rotation. 

5. Final 

Countdown:

  When PowerPanel Plus™ detects that the utility voltage is below 85 volts or above 150 volts, the 

Final Countdown

 will begin.  

When the countdown reaches zero, PowerPanel Plus™ will save and close any open applications, and then shut down the operating system in an 
intelligent and orderly manner. 

6. Approximate 

Backup 

Time:

  This indicator shows the 

approximate

 amount of backup time that is available, based upon the battery capacity and 

the load on the system.  This indicator can appear in red, yellow, or green, depending upon the number of minutes available. 

7. Scheduled 

Off:

  PowerPanel Plus™ can be set to automatically shutdown the computer system at a user specified time.  

Scheduled Off

 settings 

that are set to occur within seven days will be displayed. 

8. Temperature:

  This indicator displays the internal operating temperature of the unit.  If the temperature exceeds 158°F (70°C), the indicator will 

change from green to red. 

Содержание CPS900AVR

Страница 1: ...User Manual for CPS900AVR and PowerPanel Plus Software User Manual ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT www cyberpowersystems com faqs htm...

Страница 2: ...source before servicing the battery or installing a computer component DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applicatio...

Страница 3: ...lets Provides three surge protected outlets to protect connected equipment against surges and spikes 3 All outlets Designed for AC Adapters Allows six AC power adapter blocks to be plugged into the UP...

Страница 4: ...a telephone cable from the wall jack outlet to the in jack of the UPS Connect a telephone cable the out jack on the UPS with the CPU icon to the modem port of the computer The out jack with the telep...

Страница 5: ...back of your computer Note You must use the cable that was supplied with the unit 10 Plug the UPS into an AC outlet turn the UPS on and then start your computer 11 Click on Start point to Settings and...

Страница 6: ...used 6 Version This shows the hardware version 7 Status Bar The area display messages about the status of the software 8 Schedule Button Click this button to access the Schedule Window POWERPANEL PLU...

Страница 7: ...the UPS without having to unplug the unit from the wall When Run is clicked the will switch to battery power and the unit will beep 8 About This button will display information about the software as w...

Страница 8: ...ow 7 Closed Application Information Option Button When this option is selected the log will display the names and location of any files that were auto saved by the software TESTING YOUR UPS SYSTEM Onc...

Страница 9: ...erload Occurs in the Battery power Supplied Outlets Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and turn the UPS on Off Off Off On...

Страница 10: ...back of the computer for an additional serial port Move the cable to this port The unit is not providing battery power Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back...

Страница 11: ...if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if...

Страница 12: ...f you do not complete a registration card you will be required to provide proof of purchase as described below to have the benefits of this Limited Warranty LIMITED WARRANTY CyberPower warrants to you...

Страница 13: ...cted Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer for the Connected Equipment and the name of the power util...

Страница 14: ...ients in such transmission 3 Damage from any circumstance described as excluded above with respect to the Product 4 Damages from fire flood wind rain rising water or leakage or breakage of plumbing fr...

Страница 15: ...nect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed...

Отзывы: