background image

CPS600E 

 

Copyright © 2010 CyberPower Systems, Inc.

 

 

3

 
 
SAFETY: 

EN62040-1-1 

 
EMI: 

Conducted Emission: IEC/EN 62040-2…Category C2

 

Radiated Emission: IEC/EN 62040-2……Category C2

 

Harmonic Current: IEC/EN61000-3-2

 

Voltage Fluctuations and Flicker: IEC/EN61000-3-3 

 
EMS:   

IEC/EN61000-4-2(ESD)

 

IEC/EN61000-4-3(RS) 

 

IEC/EN61000-4-4(EFT)

 

IEC/EN61000-4-5(lightning surge)

 

IEC/EN61000-2-2 (Immunity to low frequency signals)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание CPS600E

Страница 1: ...0E CyberPower Europe CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 0 40 2348170 Fax 31 0 40 2340314 Website http eu cyberpowersystems com E mail sales cyberpower eu...

Страница 2: ...ACKING 4 AUTOMATIC VOLTAGE REGULATOR 4 HARDWARE INSTALLATION GUIDE 4 BASIC OPERATION 5 DESCRIPTION 5 REPLACING THE BATTERY 6 DEFINITIONS FOR ILLUMINATED LCD 7 EPS STATUS INQUIRY AND FUNCTIONS SETUP 8...

Страница 3: ...he CE requirement CAUTION The building wiring socket outlet shockproof socket outlet must be easily accessible and close to the EPS CAUTION Please use only VDE tested CE marked mains cable e g the mai...

Страница 4: ...EN 62040 2 Category C2 Radiated Emission IEC EN 62040 2 Category C2 Harmonic Current IEC EN61000 3 2 Voltage Fluctuations and Flicker IEC EN61000 3 3 EMS IEC EN61000 4 2 ESD IEC EN61000 4 3 RS IEC EN6...

Страница 5: ...the EPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e...

Страница 6: ...Inquiry and Functions Setup section for more details 5 AC Outlet The unit has one Schuko type outlet for connected equipment to ensure temporary uninterrupted operation during a power failure Max Out...

Страница 7: ...es regarding proper disposal of batteries Lead acid batteries should be recycled CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION...

Страница 8: ...ays normal line mode AVR mode and battery backup mode 3 NORMAL MODE Icon This icon will illuminate when the EPS is working under normal conditions 4 ON BAT On Battery Icon When a severe brownout or bl...

Страница 9: ...nctions User configurable functions are as follows a Delay Time The time delay between switching from Battery Mode to Line Mode There are 9 different settings The default setting is 0 minute Function...

Страница 10: ...to select the robust mode setting 1 and using the computers is suggested to select the standard mode setting 2 The settable items are sorted by unit as in the following table Step 3 Press and hold th...

Страница 11: ...y and the alarm reacts during the machine shut down LCD Warning Display Alarm Condition Solution Over Load Icon Constant tone Over Load Output Off Load exceed the rating of EPS Check total load to con...

Страница 12: ...ct CyberPower Systems at service cyberpower eu com Batteries are discharged Recharge the unit for at least 4 hours Unit has been damaged by a surge or spike Contact CyberPower Systems about replacemen...

Страница 13: ...0 230Vac On Battery Output Frequency 50 60 Hz 1 Overload Protection On Utility Fuse On Battery Internal Current Limiting Transfer Time 10 ms Typical Output Receptacles Schuko Type 1 External Battery V...