CyberPower CPS1000AVR Скачать руководство пользователя страница 1

CPS1000AVR  

Guaranteed Uninterruptible Power System

 

 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

 

1. 

Make sure that the total Volt-Amp (VA) requirements of your computer, monitor and peripheral equipment does 
not exceed 1440VA. 

2. 

Insure that the equipment plugged into the three battery power-supplied outlets does not exceed the UPS unit’s 
rated capacity (1000VA/500W for CPS1000AVR).    If rated unit capacities are exceeded, an overload 
condition may occur and cause the UPS unit to shut down or the circuit breaker to trip. 

3. 

If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert Watts (W) or 
Amps (A) into VA by doing the calculations below.    Note:    The below equation only calculates the maximum 
amount of VA that the equipment can use, not what is typically used by the equipment at any one time.    Users 
should expect usage requirements to be approximately 60% of below value. 

 

TO ESTIMATE POWER REQUIREMENTS: 

 

           Watts (W) x 1.82 =          VA or        Amps (A) x 120 =       VA 
Add the totals up for all pieces of equipment and multiply this total by .6 to calculate actual requirements There are 
many factors that can affect the amount of power that your computer system will require.    The total load that you will 
be placing on the battery-powered outlets should not exceed 80% of the unit’s capacity. 
 

 

INSPECTION 

 
The box should contain the following: 
(1) PowerPanel Plus™ software (floppy disk); (1) serial interface cable (DB-9); (1) serial to USB adapter cable; (1) telephone 
communication cable; (1) user manual; (1) warranty registration card; (1) UPS unit. 

 

 

DESCRIPTION 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 
 
 
 
 
 

 

 

 

 

HARDWARE INSTALLATION GUIDE 

 

7.  

Electrical Wiring Fault Indicator 

This LED indicator will illuminate to warn the user 
that a wiring problem exists 

with the AC outlet

.  

If this LED is illuminated, user is advised to 
unplug all electrical equipment from the outlet and 
have an electrician check the outlet to insure 
proper wiring. 

8.  AVR Indicator 

This LED indicates that the UPS is operating in 
automatic voltage regulation mode. 

9.  Using Battery Indicator 

This illuminates during a utility failure, indicating 
that the battery is supplying power to the battery 
power supplied outlets. 

10.  Check Battery 

This illuminates indicating a weak battery.    If the 
indicator is still illuminated after allowing the unit 
to charge for 12 hours, replace the battery 
according to the instructions in the 

Replacing the 

Battery

 section of this manual. 

11.  Serial Port to PC 
This port allows connection and 

communication from the DB-9 serial or USB port 
on the computer to the UPS unit.    The UPS 
communicates its status to the PowerPanel 
Plus™ software.    This interface is also 
compatible with the UPS service provided by 

Windows NT, Windows 2000 and Windows XP. 
12.  Communication Protection Ports 

Communication protection ports will protect any 
standard modem, fax, or telephone line. 

1.  

Battery Backup and Surge Protection Outlets 

Provides three battery-supplied outlets with 
Automatic Voltage Regulation for consistent output 
power to connected equipment. 

2.

 

  “Always-On” Surge Protection Outlets 

Provides three surge-protected outlets to protect 
connected equipment against surges and spikes. 

3.    All outlets Designed for AC Adapters 

Allows six AC power adapter blocks to be plugged 
into the UPS without making adjacent outlets 
inaccessible. 

4.  Resettable Circuit Breaker 

Located on the side of the UPS, the circuit breaker 
provides circuit overload and fault protection.   
Under normal operating conditions, the circuit 
breaker is depressed. 

5.  Power Switch 

Can be used as the master on/off switch for 
computer equipment connected to the battery power 
supplied outlets. 

6.    Power On Indicator 

This LED is illuminated when the utility condition is 
normal and the UPS outlets are providing

 “clean”   

power, free of surges and spikes.   

Содержание CPS1000AVR

Страница 1: ...unplug all electrical equipment from the outlet and have an electrician check the outlet to insure proper wiring 8 AVR Indicator This LED indicates that the UPS is operating in automatic voltage regul...

Страница 2: ...jack on the UPS with the CPU icon to the modem port of the computer The out jack with the telephone icon can be used to protect a telephone or fax machine line 5 Plug the UPS into a properly grounded...

Страница 3: ...and unplug it 9 Connect the serial interface to the UPS and an open serial port on the computer Note You must one of the cables that was supplied with the unit 10 Plug the UPS into an AC outlet turn t...

Страница 4: ...PANEL PLUS SOFTWARE USER MANUAL PowerPanel Plus version 1 13 or greater is designed for use with Windows 95 Windows 98 Windows Me Windows NT and Windows 2000 The latest version can be downloaded from...

Страница 5: ...ad on the system This indicator can appear in red yellow or green depending upon the number of minutes available 7 Scheduled Off PowerPanel Plus can be set to automatically shutdown the computer syste...

Страница 6: ...f AC power To maximize battery life it is recommended to keep this disabled 6 Default Restores the settings to the factory defaults 7 Cancel Exits the window without saving changes 8 OK Exits the wind...

Страница 7: ...hat the UPS has been charged for at least 4 hours before performing this test If you are using PowerPanel Plus 1 With your UPS and computer on open an application such as notepad 2 Enter some data int...

Страница 8: ...Do not lay tools or metal parts on top of battery or any terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground...

Страница 9: ...sintheBattery power SuppliedOutlets TurntheUPSoffandunplug atleastonepieceofequipmentfromtheUPS Wait5seconds resetthecircuitbreakerand turntheUPSon On On Off On Fla sh Off Off On Set None WeakBattery...

Страница 10: ...an additional serial port Move the cable to this port The unit is not providing battery power Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the...

Страница 11: ...t and therefore entitled coverage under the Limited Warranty and the Power Control Guarantee Registration is not required for Limited Warranty coverage but note if you do not complete a registration c...

Страница 12: ...ample a sales receipt that establishes you as the Initial Customer the original consumer purchaser of the Product within ten 10 days of the event for which you want to make a claim for warranty servic...

Страница 13: ...ded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10 100T Ethernet lines wh...

Отзывы: