User’s Manual   

K01-AE55000

 

IMPORTANT SAFETY WARNINGS 

 

(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the 

unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 

CAUTION!  

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive 

contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!  

To reduce the risk of electric shock, do not remove the cover except to service the battery.    No user serviceable parts inside 

except for battery. 

CAUTION!  

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!  

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into an outlet that is not 

grounded.    If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!  

To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a 

computer component. 

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!   

CyberPower Systems does not sell products for life support or medical 

applications.  

DO NOT

 use in any circumstance that would affect operation or safety of any life support equipment or with any medical 

applications or patient care. 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an aquarium.

   

Condensation from the aquarium can cause the unit to short out. 

DO NOT USE WITH LASER PRINTERS!   

The power demands of these devices will overload and possibly damage the unit. 

 
 

INSTALLING YOUR UPS SYSTEM   

 
 

UNPACKING 

 
Inspect the UPS upon receipt. The box should contain the following: 

(1) UPS unit; (1) User’s manual; (1) PowerPanel™ Personal Edition software CD; (1) USB device cable; (1) Telephone cable; (1) Warranty 

registration card 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

 

 

1.

  Make sure that the total Volt-Amp (VA) requirements of your computer, monitor and peripheral equipment does not exceed 1440VA. 

2.

  Ensure that the equipment plugged into the four battery power-supplied outlets does not exceed the UPS unit’s rated capacity 

(550VA/330W for CP550SL / AE550).    If rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to 

shut down or the circuit breaker to trip.     

3.

  If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert Watts (W) or Amps (A) into VA by 

doing the calculations below.    Note:    The below equation only calculates the maximum amount of VA that the equipment can use, not 

what is typically used by the equipment at any one time.    Users should expect actual usage values to be approximately 60% of the 

calculated values.    To estimate power requirements: 

                      Watts (W) x 1.67 =                        VA or                       Amps (A) x 120 =            VA 

Add the totals up for all pieces of equipment and multiply this total by .6 to calculate actual power requirements. 

There are many factors that can affect the amount of power that your computer system will require.    The total load that you will be 

placing on the battery-powered outlets should not exceed 80% of the unit’s capacity.     

 

HARDWARE INSTALLATION GUIDE 

 

1.  Your new UPS may be used immediately upon receipt.    However, 

recharging the battery 

for at least 16 hours

 is recommended to insure that the battery’s maximum charge 

capacity is achieved.    A loss of charge may occur during shipping and storage.    To 

recharge the battery, simply leave the unit plugged into an AC outlet.    The unit will charge 

in both the ON as well as the OFF position. If you wish to use the software, use the enclosed 

USB device cable to connect the UPS to your computer. If you are not going to use the 

software, you do not need to connect the cable. 

2.  With the UPS unit turned off and unplugged, connect your computer, monitor and any externally powered data storage device (Zip drive, 

Jazz drive, Tape drive, etc…) into the battery power supplied outlets.    Plug your peripheral equipment (printer, scanner, speakers) into 

the full-time surge protection outlets.   

DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum or other large 

electrical device into the UPS.    The power demands of these devices will overload and possibly damage the unit. 

3.  To protect a fax, phone or modem, connect a telephone cable from the wall jack outlet to the in jack of the UPS.   

Connect a telephone cable from the out jack with the CPU icon to the modem port on your computer. The out jack 

with the telephone icon can be used to protect a telephone or fax machine. 

4.  Plug the UPS into a 2 pole, 3 wire grounding receptacle (wall outlet).    Make sure the wall branch outlet is protected 

by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. refrigerator, copier, 

etc…).    The warranty prohibits the use of extension cords, outlet strips, and surge strips. 

5.  Press the power switch to turn the unit on.    The power on indicator light will illuminate and the unit will “beep” once. 

6.  If an overload is detected, an audible alarm will sound and the unit will emit one long beep.    To correct this, turn the UPS off and unplug 

at least one piece of equipment from the battery power supplied outlets.    Wait 10 seconds.    Make sure the circuit breaker is depressed 

and then turn the UPS on. 

7.  Your UPS is equipped with an auto-charge feature.    When the UPS is plugged into an AC outlet, the battery will automatically recharge. 

8.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

9.  To store your UPS for an extended period, cover it and store with the battery fully charged.    While in storage recharge the battery every 

three months to insure battery life. 

 

BASIC OPERATION 

 

DESCRIPTION 

 

 

Battery and Surge Protected Outlets 

The unit has four battery powered/surge protected outlets for 

connected equipment and ensures temporary uninterrupted 

operation of your equipment during a power failure. 

 

Full-Time Surge Protection Outlets 

The unit has four always on surge suppression outlets. 

 

Power Switch 

Can be used as a master on/off switch for equipment 

connected to the battery power supplied outlets. 

 

 

 

 

Power On Indicator 

This LED is illuminated when the utility condition is normal and the UPS outlets are providing power, free of surges and spikes. 

 

Electrical Wiring Fault Indicator 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.   

If this is illuminated, user is advised to disconnect all electrical equipment from the outlet and have an electrician check to ensure the 

outlet is properly wired. The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet. 

 

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax or telephone line.

 

 

Circuit Breaker 

Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.   

 

 

Serial/USB Ports to PC 

The ports allow connection and communication from the USB or DB-9 serial port on the computer to the UPS unit.    The UPS 

communicates its status to the PowerPanel™ Personal Edition software.    This interface is also compatible with the Power 

Management UPS control provided by Windows

R

 2000 and Windows

R

 XP. 

Note: Only one of these two ports can be used to communicate with your computer at one time.   

Note: To install PowerPanel™ Personal Edition Software the computer will need Microsoft

R

  Internet Explore 5.0 or higher 

installed. 

Note: If using the Serial Port, users need to download Power Panel

R

  software from our website 

http://www.cyberpowersystems.com

 and order the standard serial cable. If you have any questions email CyberPower 

technical support for help. 

[email protected]

 

 

 

Outlets Designed for AC Adapters 

The unit has four outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets. 

 

Vertical Use   

The unit can be placed on it’s end in a vertical orientation. 

Note: We recommend you place the unit next to the wall when standing the unit vertically. 

 

REPLACING THE BATTERY 

 

CAUTION!  

Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery.    Service the battery under the 

supervision of personnel knowledgeable of batteries and their precautions. 

CAUTION!

    Use only the specified type of battery.    See your dealer for replacement batteries.

 

CAUTION!  

The battery may present a risk of electrical shock.    Do not dispose of battery in a fire as it may explode. Follow all local 

ordinances regarding proper disposal of batteries.    Almost any retailer that sells lead-acid batteries collects used batteries for recycling, as 

required by most state laws. 

CAUTION!

    Do not open or mutilate the batteries.    Released electrolyte is harmful to skin and eyes and may be toxic.

 

CAUTION!  

A battery can present a high risk of short circuit current and electrical shock.    Take the following precautions before replacing 

the battery: 

1.  Remove all watches, rings or other metal objects. 

2.  Only use tools with insulated handles. 

3.  Do not lay tools or metal parts on top of battery or any terminals. 

4.  Wear rubber gloves and boots. 

5.  Determine if the battery is inadvertently grounded. If grounded, remove the source of ground. 

CONTACT WITH GROUNDED BATTERY 

CAN RESULT IN ELECTRICAL SHOCK!

 

 

TO REPLACE THE BATTERY 

1.  Turn off and unplug all connected equipment. 

2.  Turn the UPS off and unplug it from the AC power source. 

3.  Turn the UPS upside down. 

4.  Remove the 1 retaining screw. 

5.  Slide the battery compartment cover completely off of the unit. 

6.  Remove the battery from the compartment. 

7.  Disconnect the battery wires from the battery. 

8.  Install the replacement battery by connecting the red wire and black wire to the positive (+) and negative (-) terminal of the battery. 

9.  Put the battery back into the compartment. 

10.  Slide back the battery compartment cover and tighten the retaining screw. 

11.  Recharge the unit for 4 – 8 hours to fully charge the battery. 

REMINDER:  

Batteries are consider 

HAZARDOUS WASTE

 and must be disposed of properly.    Almost any retailer that sells lead-acid 

batteries collects used batteries for recycling, as required by most state laws. 

 

 

TROUBLE SHOOTING 

 

Problem

 

Possible Cause 

Solution

 

Full-time surge protection outlets 
stop providing power to 
equipment. Circuit breaker 
button is projecting from the side 
of the unit.

 

Circuit breaker has tripped due to an 
overload. 

Turn the UPS off and unplug at least one piece of equipment.   
Wait 10 seconds, reset the circuit breaker by depressing the 
button, and then turn the UPS on.

 

Battery not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

The UPS does not perform 
expected runtime. 

Battery is slightly worn out. 

Contact CyberPower Systems about replacement batteries at 
[email protected] 

The on/off switch is designed to 
prevent damage by rapidly turning it 
off and on. 

Turn the UPS off.    Wait 10 seconds and then turn the UPS on. 

The unit is not connected to an AC 
outlet. 

The unit must be connected to a 110/120v 60Hz outlet. 

The battery is worn out. 

Contact CyberPower Systems about replacement batteries at 
[email protected] 

The UPS will not turn on. 
 

Mechanical problem. 

Contact CyberPower Systems at 
[email protected] 

The USB / serial cable is not 
connected. 

Connect the USB / serial cable to the UPS unit and an open 
USB / serial port on the back of the computer.    You must use 
the cable that came with the unit. 

The USB / serial cable is connected 
to the wrong port. 

Check the back of the computer for an additional USB / serial 
port.    Move the cable to this port. 

The unit is not providing battery 
power. 

Shutdown your computer and turn the UPS off.    Wait 10 
seconds and turn the UPS back on.    This should reset the unit. 

PowerPanel™ Personal Edition 
is inactive (all icons are gray). 

The serial cable is not the cable that 
was included with the UPS unit. 

If you are using a serial cable you must use a CyberPower serial 
cable.    If you need this cable please contact technical support.   

[email protected]

   

 

Additional troubleshooting information can be found at 

www.cyberpowersystems.com/support.htm 

 

TECHNICAL SPECIFICATIONS 

 

Model 

CP550SL / AE550 

Capacity 

550VA / 330W 

Input Voltage on Utility 

100V to 140V 

Input Frequency 

57 Hz to 63 Hz 

On-Battery Output Voltage 

120Vac ± 5% 

Transfer Time 

4ms Typical 

Max. Load for UPS Outlets (4 Outlets) 

550VA / 330W 

Max. Load for Full-Time Surge Protection outlets (8 Outlets) 

12 Amps 

On-Battery Output Wave Form 

Simulated Sine Wave Form 

Operating Temperature 

+ 32°F to 95° F / 0° C to 35° C 

Operating Relative Humidity 

0 to 95% NON-CONDENSING 

Size (L x W x H) 

10 2/3” x 6 1/2” x 3 1/2” / 27.1cm x 16.5cm x 8.7cm 

Net Weight 

12.5 lbs 

Typical Battery Recharge Time 

8 hours typical from total discharge 

Typical Battery Life 

3 to 6 years, depending on number of discharge/recharge cycles 

Battery Type 

12V / 8.0AH 