CyberPower BR450E Скачать руководство пользователя страница 4

4

 

 

Hardware Installation Guide

 

 

1. Your new UPS may be used immediately upon receipt. However, recharging the battery for 

at least 8 hours is recommended to ensure that the battery's maximum charge capacity 
is achieved. Charge loss may occur during shipping and storage. To recharge the battery, 
simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off 
position. 

2. If you will use the software, connect the USB cable to the USB port on the UPS. 
3. With the UPS unit off and unplugged, connect the computer, monitor, and any externally 

powered data storage device (Zip drive, Jazz drive, Tape drive, etc. into the battery power 
supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper 
shredder or other large electrical device into the battery power supplied outlets.   
The power demands of these devices will overload and possibly damage the unit. 

4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall 

branch outlet is protected by a fuse or circuit breaker and does not service equipment with 
large electrical demands (e.g. air conditioner, refrigerator, copier, etc. Avoid using 
extension cords. If used, the extension cord must be grounded and rated for 15 amps. 

5. Depress the power switch to turn the unit on. The power on indicator light will illuminate 

and the unit will "beep". 

6. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. 

To correct this, turn the UPS off and unplug at least one piece of equipment from the 
battery power supplied outlets. Wait 10 seconds. Make sure the circuit breaker is 
depressed and then turn the UPS on. 

7. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC 

outlet, the battery will automatically recharge. 

8. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 
9. To store your UPS for an extended period, cover it and store with the battery fully 

charged. Recharge the battery every three months to ensure battery life. 

 

CYBERPOWER GREENPOWER UPS TECHNOLOGY 

 

Our new UPS circuit is designed to save energy operating in GreenPower   
Bypass Mode.

 

 

A traditional UPS circuit with AVR provides normal output voltage through the   
Relay and AVR transformer. The current travels first through the transformer   
conducting energy and generating heat. This heat creates energy dissipation   
resulting in a "Power Loss" or consumption of utility power and money. 
CyberPower's GreenPower Circuit Design is a solution to this "Power Loss. 
" When the Utility Power is operating normally, our Green Power UPS works in   
Bypass Mode. Our GreenPower design conducts power only through the Relay and still provides 
normal output voltage. Bypassing the transformer reduces power consumption thereby conserving 
energy and saving money. When the utility power is abnormal the UPS will operate under Battery or 
AVR Mode. Under this condition Green Power UPS and a traditional UPS would operate about the 
same. 
On average utility power operates 88% of the time and the CyberPower GreenPower Technology will 
work in its money/energy saving Bypass Mode.

 