power outlet with fuse or circuit breaker protection. The Battery 
modules grounded are through the UPS.

 

 

CAUTION!   

The battery can power hazardous components 

inside the unit, even when the AC input power is disconnected.

 

 

CAUTION!   

To prevent the risk of fire or electric shock, install in 

a temperature and humidity controlled indoor area, free of 
conductive contaminants. (Please see specifications for 
acceptable temperature and humidity range).

 

 

CAUTION!    (No User Serviceable Parts):

 Risk of electric shock, 

do  not  remove  cover.  No  user  serviceable  parts  inside.  Refer 
servicing to qualified service personnel. 

 

CAUTION!    (Non-Isolated Battery Supply): 

Risk of electric 

shock, battery circuit is not isolated from AC power source; 
hazardous voltage may exist between battery terminals and 
ground. Test before touching.

 

 

CAUTION!   

Wiring must be done by qualified personnel.

 

 

CAUTION!    DO NOT USE WITH OR NEAR AQUARIUMS!

 

To reduce the risk of fire, do not use with or near aquariums.   
Condensation from the aquarium can come in contact with 
metal electrical contacts and cause the machine to short out. 

 

CAUTION!   

Do not dispose of batteries in fire as the battery 

may explode. 

 

CAUTION!   

Do not open or mutilate the battery, released 

electrolyte is harmful to the skin and eyes. 

 

CAUTION!   

A battery can present a risk of electric shock and 

high short circuit current. The following precaution should be 
observed when working on batteries 

1.

 

Remove watches, rings or other metal objects. 

2.

 

Use tools with insulated handles. 

Содержание BPSE240V82A

Страница 1: ...ant instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate the Battery...

Страница 2: ...of electric shock battery circuit is not isolated from AC power source hazardous voltage may exist between battery terminals and ground Test before touching CAUTION Wiring must be done by qualified pe...

Страница 3: ...any other cables are connected DO NOT INSTALL THE UNIT WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE SERVICING OF BATTERIES SHOULD BE PERFORMED OR SUPERVISED BY PERSONNEL...

Страница 4: ...4 SCHEMATIC FRONT REAR PANEL DESCRIPTION BAT OUTPUT BAT INPUT Breaker Battery String1 Battery String2 BAT OUTPUT BAT INPUT Breaker Terminal Block Self locking frame BASIC OPERATION...

Страница 5: ...LE UPS WITH ONE BATTERY MODULE Step 1 First turn off the Breaker then loosen the screws to remove the Terminal block Cover of Battery Module Step 2 Connect the Battery Cable to Terminal block and ensu...

Страница 6: ...6 Step 3 Connect the Battery Cable to UPS and ensure the polarity is right Step 4 Retighten the Terminal Block Cover of Battery Module and UPS...

Страница 7: ...Maintenance Free Lead Acid Battery 12V 9Ah x20pcs x2sets Rated Battery Voltage 240Vdc Overload Protection Breaker 100A 125Vdc 3P Physical Maximum Dimensions HxWxD mm 718x260x550 Weight kg 124 Environm...

Отзывы: