CyberPower 2POSTKIT Скачать руководство пользователя страница 2

OL1000RTXL2U, OL1000RTXL2UN, OL1500RTXL2U, 
OL1500RTXL2UN, OL2200RTXL2U, OL2200RTXL2UN,
OL3000RTXL2U, OL3000RTXL2UN, OL3000RTXL2UHVN, 
OL5KRTHD, OL6KRTHD, OL8KRTHD, OL10KRTHD, 
OL1000ERTXL2U, OL1500ERTXL2U, OL2000ERTXL2U, 
OL3000ERTXL2U, OL5KERTHD, OL6KERTHD, OL8KERTHD, 
OL10KERTHD, OL6KRT, OL6KRTF, OL6KRTMB, OL6KRTMBTF, 
OL6KRTHW, OL8KRT, OL8KRTF, OL8KRTMB, OL8KRTMBTF, 
OL8KRTHW, OL10KRT, OL10KRTF, OL10KRTMB, OL10KRTMBTF, 
OL10KRTHW, OL6000ERT3U, OL6000ERT3UD, OL6000ERT3UP, 
OL8000ERT3U, OL8000ERT3UD, OL8000ERT3UP, 
OL10000ERT3U, OL10000ERT3UD, OL10000ERT3UP, OL5KSTF, 
OL6KSTF, OL10KSTF, OL6000RT3UTAA, OL6KRT2UTFHWIORTAA

PR750RT2U, PR1000RT2U, PR1500RT2U, PR2000RT2U, 
PR2200RT2U, PR3000RT2U, PR750RTXL2U, PR1000RTXL2U, 
PR1500RTXL2U, PR2000RTXL2U, PR2200RTXL2U, 
PR3000RTXL2U, PR2200RTXL2UA, PR3000RTXL2UA, 
PR2200RTXL2UHVA, PR3000RTXL2UHVA, PR1000RT2UN, 
PR1500RT2UN, PR2000RT2UN, PR2200RT2UN, PR3000RT2UN, 
PR1500RTXL2UN, PR2000RTXL2UN, PR2200RTXL2UN, 
PR3000RTXL2UN, PR2200RTXL2UAN, PR3000RTXL2UAN, 
PR2200RTXL2UHVAN, PR3000RTXL2UHVAN, PR750ERT2U, 
PR1000ERT2U, PR1500ERT2U, PR2000ERT2U, PR2200ERT2U, 
PR3000ERT2U, PR750ERTXL2U, PR1000ERTXL2U, 
PR1500ERTXL2U, PR2000ERTXL2U, PR2200ERTXL2U, 
PR3000ERTXL2U, PR2200ERTXL2UA, PR3000ERTXL2UA, 
PR2200ERTXL2UAN, PR3000ERTXL2UAN, PR1000RTXL2UTAA, 
PR1500RTXL2UTAA, PR2000RTXL2UTAA, PR3000RTXL2UTAA

Step 4: Secure the unit to the rack

Secure the unit to your rack with four screws at the front of the 
rack. (Holes 2 and 5 as shown below) Once completed, perform the 
same steps 1-4 for the other module.

Step 3: Rackmount ears installation

If there is a dust cover on the side, remove it from screw hole. 
Attach the included rackmount ears to the center holes on the 
sides of the unit by using the screws as shown below. 

2-POST RACKMOUNT KIT INSTALLATION INSTRUCTIONS

Position 5

Position 2

INSTALLATION

COMPATIBILITY LIST FOR CYBERPOWER PRODUCT

Step 2: Adjust rackmount kit to fit your rack and secure the kit

The mounting depth of the kit can adjust from 2.9 inches to 3.9 
inches (7.4 cm to 10 cm). 
Adjust the depth to match your rack depth. Secure each 
rackmount kit to your rack with four screws at the front of the rack 
(square holes 1 and 4 as shown below). Secure the kit to the rear 
of the rack with four screws (square holes 2 and 4 as shown below).

Position 2

Position 4

Position 2

Position 4

Position 4
Position 1

Position 4
Position 1

INSTALLATION

Cyber Power Systems, Inc. | 

www.CyberPowerSystems.com

For USA and Canada | 

4241 12th Ave East, Suite 400, Shakopee, MN 55379 | Toll-free: 877.297.6937

For all other regions | 

Please visit our website for local contact information.

Copyright © 2021 Cyber Power Systems, Inc. All rights reserve.

BP36V60ART2U, BP72V60ART2U, BP144VL2U01, BP192VL2U01, 
BPE36V60ART2U, BPE72V60ART2U, BPE36V60ART2US, 
BPE72V60ART2US, BPE144VL2U01, BPE192VL2U01, BP240VL3U01, 
BP240VL3U02, BPE240V30ART3U, BPE240V50ART3U, 
BPE240V30ART3US, BPE240V50ART3US, BP48VP2U01, 
BP48VP2U02, BP48VP2U03, BP48VP2U02TAA

Отзывы: