CyberOptics Corporation
115
Conveyor Components
Changing the Position of the Mechanical Board Stop
Use this procedure to change the position of the mechanical board stop. This procedure can be
performed with access to the left/right of the machine in production line. This section shows
the procedure performed when the machine is not in production line.
➢
To change the position of the mechanical board stop
1. Turn off all electrical power to the system. For more information, refer to the section
2. Make sure the machine is OFF and the rails are in HOME position.
3. Unscrew the two thumb screws.
Figure 69.
Stopper Sensor Bracket Thumb screws
4. Remove the stopper sensor bracket from the conveyor. Re-tightened the thumb screws back.
5. Unlock the two wing nuts and keep the wing nuts in a safe place.
Figure 70.
Stopper Bracket Wing nuts
Thumb screws
Stopper sensor
bracket
Wing Nuts