background image

CyberData Corporation

930260A

Operations Guide

 Installing the VoIP Indoor Intercom

 

Intercom Setup

6

2.2 Intercom Setup

2.2.1 VoIP Intercom Connections

Figure 2-4

 shows the pin connections on the J7 (terminal block). This terminal block can accept a 

wire range from 16 AWG to 26 AWG. 

Note

As an alternative to using PoE power, you can supply 5 VDC at 1000 mA into the terminal 
block.

Figure 2-4. VoIP Intercom Connections

Alternate Power Input: 
1 = +5V at 1000 mA 
2 = Power Ground

Relay Contact:
(2A at 30 VDC or 0.4A at 125 VAC
 for continuous loads)
3 = Normally Open Common
4 = Normally Open Contact
5 = Door Sense Input
6 = Door Sense Ground Reference

J3  -  Terminal Block

Wire in,
accept wire range
from 16-26 AWG

3

4

 

Содержание VoIP Indoor Intercom 011030

Страница 1: ...VoIP Indoor Intercom Operations Guide Part 011030 Document Part 930260A for Firmware Version 3 3 2 CyberData Corporation 2555 Garden Road Monterey CA 93940 831 373 2601...

Страница 2: ...r such products software firmware and or hardware CyberData Corporation reserves the right to make changes without notice to this manual and to any such product software firmware and or hardware OPEN...

Страница 3: ...e obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments acces...

Страница 4: ...hat is a safety policy or protection of property The safety guidelines for the equipment in this manual do not purport to address all the safety issues of the equipment It is the responsibility of the...

Страница 5: ...CyberData Corporation 930260A Operations Guide Revision History Revision Date Released Description of Changes A 1 7 2009 This is the first release of the manual...

Страница 6: ...CyberData Corporation 930260A Operations Guide...

Страница 7: ...r 13 2 2 7 Adjust the Volume 14 2 3 Configure the Intercom Parameters 15 2 3 1 Log in to the Configuration Home Page 15 2 3 2 Configure the Network Parameters 17 2 3 3 Set up the Intercom 19 2 3 4 Con...

Страница 8: ...CyberData Corporation 930260A Operations Guide ii...

Страница 9: ...ercom is a SIP endpoint designed to provide VoIP phone connectivity in a tamper proof and secure package Figure 1 1 Figure 1 2 and Figure 1 3 illustrate how the VoIP Indoor Intercoms can be installed...

Страница 10: ...ercom enclosure is not rated for any AC voltages Warning Electrical Hazard This product should be installed by a licensed electrician according to all local electrical and building codes Warning Elect...

Страница 11: ...urable door or intrusion sensor settings Network configurable relay activation settings Dial Out Extension supports the addition of comma delimited pauses before sending additional DTMF tones Network...

Страница 12: ...Intercom capabilities RTP RTP AVP Audio Video Profile Audio Encodings PCMU G 711 mu law PCMA G 711 A law Packet Time 20 ms 1 4 Supported SIP Servers The following link contains information on how to c...

Страница 13: ...Installing the VoIP Indoor Intercom 2 1 Parts List Table 2 1 illustrates the SiP VoIP and PoE Speaker parts Table 2 1 Parts List Quantity Part Name Illustration 1 Intercom Assembly 1 Installation Quic...

Страница 14: ...wire range from 16 AWG to 26 AWG Note As an alternative to using PoE power you can supply 5 VDC at 1000 mA into the terminal block Figure 2 4 VoIP Intercom Connections Alternate Power Input 1 5V at 10...

Страница 15: ...Installing the VoIP Indoor Intercom Intercom Setup Operations Guide 930260A CyberData Corporation 7...

Страница 16: ...ce with RFC2833 DTMF generation Figure 2 5 Auxiliary Relay Wiring Diagram Warning Electrical Hazard The VoIP Intercom enclosure is not rated for any AC voltages Warning Electrical Hazard This product...

Страница 17: ...tions Guide 930260A CyberData Corporation 9 2 2 3 Identifying the VoIP Intercom Connectors See Figure 2 6 Figure 2 7 and Table 2 2 to identify the connectors and functions Figure 2 6 J2 J5 and J6 Conn...

Страница 18: ...e 2 2 for the connector settings Table 2 2 Connector Settings Jumper Setting J1 PoE Network Connection RJ 45 ethernet J4 J Tag Factory only J3 Terminal Block see Figure 2 4 JP2 Call Button LED interfa...

Страница 19: ...The first blink indicates that the Interfom has acquired its network settings The second blink indicates that the Interfom is operational 2 2 4 2 Calling You may initiate a call by pressing the Call b...

Страница 20: ...ply The square green Link light above the Ethernet port indicates that the network connection has been established see Figure 2 10 The Link light changes color to confirm the auto negotiated baud rate...

Страница 21: ...r to final assembly Please remember to remove the RTFM switch jumper prior to final assembly Figure 2 11 RTFM Switch Jumper 2 2 6 1 Announcing the IP Address To announce an Intercom s current IP addre...

Страница 22: ...settings To restore the factory default settings 1 Complete steps 1 through 4 in Section 2 2 6 1 Announcing the IP Address 2 Press and hold the Call button for 10 seconds 3 When you hear the announce...

Страница 23: ...s For the initial configuration of the Intercom open your browser to the default IP address http 192 168 3 10 Note Make sure that the PC is on the same IP network as the Intercom Note You may also dow...

Страница 24: ...thernet address IP Addressing Shows the current IP addressing setting DHCP or static IP Address Shows the current IP address Subnet Mask Shows the current subnet mask address Default Gateway Shows the...

Страница 25: ...ameters indicated in Table 2 5 Link to the SIP Setup web page Link to the Upgrade Firmware web page Table 2 4 Home Page Overview Web Page Item Description Table 2 5 Network Setup Parameters Web Page I...

Страница 26: ...as the Intercom open a browser with the new IP address of the Intercom Default Gateway Enter the Default Gateway address DNS Server 1 Enter the DNS Server 1 address DNS Server 2 Enter the DNS Server 2...

Страница 27: ...Intercom Configure the Intercom Parameters Operations Guide 930260A CyberData Corporation 19 2 3 3 Set up the Intercom 1 Click the Intercom Setup button to open the Intercom Setup page See Figure 2 15...

Страница 28: ...this will activate the relay for a user selectable amount of time when the button is pressed Relay on Button Press Timeout in seconds Type the desired number of seconds for the timeout on the relay af...

Страница 29: ...ameters Operations Guide 930260A CyberData Corporation 21 3 After changing the parameters click Save Settings Link to the SIP Setup page Link to the Sensor Setup page Link to the Upgrade Firmware page...

Страница 30: ...parameters indicated in Table 2 7 Table 2 7 SIP Setup Parameters Web Page Item Description SIP Server Enter the SIP server represented as either a numeric IP address in dotted decimal notation or the...

Страница 31: ...nes using rfc2833 The first comma will pause three seconds after a call is first established with a remote device Subsequent commas will pause for two seconds A pause of one second will be sent after...

Страница 32: ...le 2 8 Table 2 8 Sensor Setup Parameters Web Page Item Description Door Sensor Flash Button LED Select Yes to flash the LED until the sensor is deactivated roughly 10 times second Activate Relay Selec...

Страница 33: ...d Activate Relay Select Yes to activate the relay until the sensor is deactivated Play Audio Locally Select Yes to loop an audio file out of the Interfom speaker until the sensor is deactivated Play A...

Страница 34: ...e CyberData website http www cyberdata net support voip intercom html 3 Unzip the Intercom version file This file may contain the following Firmware file Release notes 4 Copy the firmware files to be...

Страница 35: ...o version 3 3 0 or later CyberData recommends that you go to the Intercom Setup page and make sure the following values are set properly Auto Answer Activate Relay on Ring Activate Relay on Button Pre...

Страница 36: ...rcom log in to the web page as instructed in Section 2 3 1 Log in to the Configuration Home Page 1 Click Upgrade Firmware to open the Firmware Upgrade page Figure 2 19 Figure 2 19 Reboot System Sectio...

Страница 37: ...the Intercom Before you mount the Intercom make sure that you have received all the parts for each Intercom Refer to Table A 1 Table A 1 Drop Ceiling Mounting Components Part of the Accessory Kit Qua...

Страница 38: ...Corporation 930260A Operations Guide Mount the Intercom 30 Figure A 20 shows how to properly mount the VoIP Intercom Figure A 20 Mounting J5 J6 J2 From Speaker To J6 To J5 From Microphone From Pushbut...

Страница 39: ...example in tftpd l s tftpboot your_directory_name B 1 2 In a Windows Environment You can find several options online for setting up a Windows TFTP server This example explains how to use the Solarwind...

Страница 40: ...CyberData Corporation 930260A Operations Guide Set up a TFTP Server 32...

Страница 41: ...onterey CA 93940 USA www CyberData net Phone 800 CYBERDATA 800 292 3732 Fax 831 373 4193 Sales Sales 831 373 2601 Extension 334 Technical Support Phone 831 373 2601 Extension 333 Email support CyberDa...

Страница 42: ...This warranty includes all parts and labor If the product is out of warranty and fails a flat rate repair charge of one half the product purchase price will be assessed Repair costs for products that...

Страница 43: ...om settings 35 IP address 15 subnet mask 15 username and password 15 web login username and password 15 default gateway 15 18 default intercom settings 14 default IP settings 15 default login address...

Страница 44: ...12 network configuration of intercom 17 network rate 4 Network Setup 17 O orange link light 12 outbound proxy 22 P packet time 4 part number 4 parts list 5 password changing for web configuration acc...

Страница 45: ...er 22 SIP servers supported 4 solarwinds 31 speaker output 4 speaker volume 16 static IP addressing 17 subnet mask 15 17 supported protocols 4 T technical support contact information 33 TFTP server 4...

Страница 46: ...CyberData Corporation 930260A Operations Guide 38...