Installing the Singlewire InformaCast® RGB (Multi-Color) Strobe
Singlewire InformaCast® RGB (Multi-Color) Strobe Setup
Operations Guide
931633A
CyberData Corporation
7
2.2 Singlewire InformaCast® RGB (Multi-Color) Strobe
Setup
2.2.1 Singlewire InformaCast® RGB (Multi-Color) Strobe Connections
shows the pin connections on the terminal block. This terminal block can accept
16 AWG gauge wire.
Note
As an alternative to using PoE power, you can 8 to +12VDC @ 1000mA Regulated
Power Supply into the terminal block.
GENERAL ALERT
Caution
Figure 2-3. Connections and Alternate Power Input
Equipment Hazard
: Contacts 1 and 2 on the terminal block are only for powering
the device from a non-PoE 12 VDC power source as an alternative to Network PoE
power. Use of these contacts for any other purpose will damage the device and void
the product warranty.
1
8
Wire (IN)
Tin Leads
Approx. 1/4” or
6mm
Terminal Block
can accept 16 AWG wire
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
3
4
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws