Quick Reference 

931350C

© 2020, CyberData Corporation, ALL RIGHTS RESERVED

© 2020, CyberData Corporation, ALL RIGHTS RESERVED

931350C

Quick Reference 

Getting Started

Take the following into consideration before you install this product:

When this secure phone case is used, the touch screen capability of the DX phone is disabled.

Due to the size and mass of this product, it is important that the Backbox is safely installed according to these installation 

instructions.

Make sure that the type of wall is capable of supporting the system and use screws that are suitable for that type of wall.

The system must be installed by qualified personnel in accordance with state and local building regulations.

Also see the 

Install the DX70 Phone to Enclosure

 (on the other page).

Locate the provided Security Torx Driver Bit (usually taped right next to the Hookswitch on the Faceplate).

Tool required to remove Security Torx Screws (an Electric Hand Drill or Powered Screwdriver)

WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation 
instructions.

WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.

WARNING: This enclosure is not rated for any AC voltages!

Hookswitch Wires to USB to Analog Audio Module Connections

Contacting CyberData

Black Wire

to Terminal

Black Wires

1

10

USB-B

Black Wire to Terminal 

Green Wire to Terminal 

Yellow Wire to Terminal 

Red Wire to Termianl  

Terminal

Audio Module

USB to Analog

Block

Armored Cord

Armored Cord

Handset Retainer

Factory Disconnected

to Terminal 5

Red Wire

Connections

Reconnect Before Fasten Faceplate Assembly to Backbox

Connector

Receptacle

Connector

Plug

Magnetic Hookswitch

Backbox

***

***

Connections

Armored Cord Handset

9

4

3

2

1

USB-A

Phone

Cable Connections

USB-B to USB-A

Sales: 831-373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website:

 

http://support.cyberdata.net/

RMA Department: 831-373-2601 ext. 136
RMA Email: [email protected]
RMA Status:

 

http://support.cyberdata.net/

Warranty Information: 

http://support.cyberdata.net/

Corporate Headquarters

CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA

Phone: 831-373-2601
Fax: 831-373-4193

http://www.cyberdata.net/

Backbox Mounting

Install a Shunt on JP2 to Enable Auto Answer Mode

Dimensions are in Inches [Millimeter]

Conduit Hole Ø 1.3 [Ø33] Fits 1" EMT Fittings

Ø1.3 [Ø33]

Conduit Hole

1.969 [50.0]

4.026 [102.3]

6.212 [157.8]

1.969 [50.0]

2.362 [60.0]

14.173 [360.0]

17.717 [450.0]

2.165 [55.0]

19.685 [500.0]

13.386 [340.0]

6.496 [165.0]

Ø0.41 [Ø10.5]

Last Updated 08/06/2020

View Shown with Hole Plug Installed.
Open Faceplate then Remove Nut from the Inside.

11/32" or 9mm Socket & Socket Wrench

Tool Required to Remove Hole Plug:

JP2

Shunt

The IP Endpoint Company

Installation Quick Reference

DX70 Secure Phone 