Installing the Singlewire InformaCast Indoor Intercom with Keypad
Configure the Sensor Configuration Parameters
Operations Guide
931640A
CyberData Corporation
72
2. On the
Sensor
page, enter values for the parameters indicated in
.
Note
The question mark icon (
) in the following table shows which web page items will be defined
after the
Toggle Help
button is pressed
.
Table 2-21. Sensor Configuration Parameters
Web Page Item
Description
Door Sensor Settings
Door Sensor Normally Closed
Select the inactive state of the door sensor. The door sensor is
also known as the Sense Input on the device's terminal block.
Door Open Timeout (in seconds)
The time (in seconds) the device will wait before it performs an
action when the on-board door sensor is activated. The action(s)
performed are based on the configured Door Sensor Settings
below. Enter up to 5 digits.
Flash Button LED
When selected, the Call button LED will flash until the on-board
door sensor is deactivated (roughly 10 times/second).
Activate Relay
When selected, the device's on-board relay will be activated until
the on-board door sensor is deactivated.
Play Audio Locally
When selected, the device will loop an audio file out of the
speaker until the door sensor is deactivated.
Make call to extension
When selected, the device will call an extension when the on-
board door sensor is activated. Use the
Dial Out Extension
field
below to specify the extension the device will call.
Dial Out Extension
Specify the extension the device will call when the on-board door
sensor is activated. Enter up to 64 alphanumeric characters.
Dial Out ID
An additional Caller identification string added to outbound calls.
Enter up to 64 alphanumeric characters.
Play recorded audio
When selected, the device will call the
Dial Out Extension
and
play an audio file to the phone answering the SIP call
(corresponds to
Door Ajar
on the
Audiofiles
page).
Repeat Sensor Message
The number of times to repeat the audio message through the
local speaker or to the remote endpoint. A value of 0 will repeat
forever. Enter a value from 0-65536.
Sensor Strobe Settings
The following strobe settings will only appear if a CyberData
Strobe product is connected to your device. If a CyberData
Strobe product is not connected to your device, you will not
see the strobe settings.
Blink Strobe on Sensor
When selected, the Strobe will blink a scene when the sensor is
triggered.
Scene
Select desired scene (only one may be chosen).
ADA Compliant
Strobe will blink ON at the specified brightness for 150ms then
OFF for 350ms during the duration of the event.
Slow Fade
Strobe will increase in brightness from 0 to the specified
brightness and back to 0 over the course of about 3.5 seconds
during the duration of the event.
Fast Fade
Strobe will increase in brightness from 0 to the specified
brightness and back to 0 over the course of about 1.5 seconds
during the duration of the event.