Installing the Singlewire InformaCast Indoor Intercom with Keypad
Configure the Sensor Configuration Parameters
Operations Guide
931640A
CyberData Corporation
71
2.4.13 Configure the Sensor Configuration Parameters
The door sensor (pins 5 and 6) on the header can be used to monitor a door's open or closed state.
There is an option on the
Sensor
page to trigger on an open or short condition on these pins. The
door sensor alarm will be activated when the
Door Open Timeout
parameter has been met.
The intrusion sensor is an optical sensor installed on the Intercom board and will be activated when
the Intercom is removed from the case.
Each sensor can trigger up to five different actions:
•
Flash the LED until the sensor is deactivated (roughly 10 times/second)
•
Activate the relay until the sensor is deactivated
•
Loop an audio file out of the Intercom speaker until the sensor is deactivated
•
Call an extension and establish two way audio
•
Call an extension and play a pre-recorded audio file
Note
Calling a preset extension can be set up as a point-to-point call, but currently can't send
delayed DTMF tones.
1. Click
Sensor
menu button to open the
Sensor
page (
Figure 2-37. Sensor Configuration Page
The strobe settings will only
appear if a CyberData Strobe
product is connected to your
device.
If a CyberData Strobe product
is not connected to your
device, you will not see the
strobe settings.
Singlewire Keypad Intercom