© 2014 CyberData Corporation ALL RIGHTS RESERVED
930445E
Quick Reference
Quick Reference
930445E
© 2014 CyberData Corporation ALL RIGHTS RESERVED
Verifying Operations and Settings
To restore the V3 Zone Controller’s factory default
settings:
1. Use a paper clip to press and hold the
RTFM
switch while all of the indicator LEDs turn off.
See the picture on the right.
2. Continue to press the RTFM switch until after
the indicator LEDs turn back on.
3. Release the RTFM switch. All of the V3 Zone
Controller settings will be restored to the
factory default settings.
4. You will hear the "Restoring defaults..." audio
message play through all ports before the
device reboots.
Front View with LEDs
Back View with RTFM Switch
Status
(
GREEN
LED)
Power Status
(
BLUE
LED)
Link
(
YELLOW
LED)
Activity
(
GREEN
LED)
The round,
BLUE
Power Status
LED on the front of the V3 Zone Controller comes on indicating that the
power is on.
The square,
YELLOW
Link
LED above the Ethernet port indicates that the network connection has been
established. The
Link
LED changes color to confirm the auto-negotiated connection speed:
•
This LED is
YELLOW
at 10 Mbps.
•
This LED is
ORANGE
at 100 Mbps.
The square,
GREEN
Activity
LED above the Ethernet port blinks when there is network activity.
The round,
GREEN
Status
LED comes on after the device is booted and initialized. This LED blinks when
the unit is operational.
The square,
GREEN
Audio
Activity
LEDs turn on solid when a Zone is being paged.
Paper clip
RTFM switch
Audio Activity
(
GREEN
LED)
Typical Zone Controller Setup Using the V3 Zone Controller
Setting Up the VoIP V3 Zone Controller
Generic PoE Switch
1
2
3
4
5
6
IP Phone
IP PBX Server
VoIP V3 Zone Controller 4-Port Audio Out
Analog Amplifiers Paging Speakers
Non PoE (with 48 VDC power supply)
Chassis Ground
Chassis Ground
PoE
To set up the V3 Zone Controller, connect the
device to your network:
Poe
•
For
PoE
, plug one end of an 802.3af Ethernet
cable into the V3 Zone Controller Ethernet port.
Plug the other end of the Ethernet cable into
your network. See the figure on the left.
Non-Poe
•
For
Non-PoE
, connect the V3 Zone Controller
to a
48VDC
power supply
. See the figure on
the left.
Chassis Ground
•
If required, connect the earth grounding wire to
the
Chassis Ground
. See the figure on the
left.