CyberData 011403 Скачать руководство пользователя страница 2

© 2016, CyberData Corporation, ALL RIGHTS RESERVED

931271C

Quick Reference 

Quick  Reference 

931271C

© 2016, CyberData Corporation, ALL RIGHTS RESERVED

Connection Options

Mono(+)/Left Spkr (+) - 12

Left Spkr (-) - 11

Right Spkr (+) - 10

Mono(-)/Right Spkr (-)  -  9

Line-Out (+)  -  8

Line-Out (-)  -  7

Line-In (-)  -  6

Line-In (+)  -  5

Relay COM  -  4

Relay NO/NC  -  3

Door Sense/Button Common (GND)  -  2

Door Sense/Button Contact (+)  -  1

CLASS II WIRING

Speaker Connections*

Line-Out Connection (10K Ohm)

Line-In Connection

Relay Connection

Sensor Connection

Line-In Connection

Sensor Connection

Relay Connection

High PIV Ultrafast
Switching Diode

Output Contacts

AC or DC-rated 

depending upon 

controlled device 

requirements

DC Power Supply 
(Max. 30 VDC @ 1A)

Solid State or 
Mechanical 
Relay

AC or DC

Power 

Source

IN

OUT

External device 
such as an 
electric door strike 
or an LED strobe 
light

When line-in is enabled on 
the device, the audio 
received from the line-in 
connection will be played 
to the speaker(s) and line-
out connection as the 
lowest priority audio.

Music Source

Paging Amplifier

*See the Operations Guide for diagrams and 
information about the connections in this section.

Paging Amplifier

Paging Amplifier

Features 

SPD  Link/Act.

PWR Status

Volume

RTFM

VoIP

Loudspeaker

Speaker Volume

Speed (SPD) LED (

AMBER

)

The 

Speed

 LED illuminates 

AMBER

 for a 100Mb link or is off for 

a 10MB link when the network link to the device is established.

Status LED (

GREEN

)

After supplying power to the device, a steady 

GREEN

 

Status

 

LED confirms that the device is operational.

Link/Activity (Link/Act.) LED (

GREEN

The 

Link/Act.

 LED blinks to indicate network traffic.

Power (PWR) LED (

GREEN

/

BLUE

)

The 

PWR

 LED is a 

GREEN

 in low power mode (

802.3af) and 

BLUE

 during high power mode (

802.3at).

RTFM Switch

To broadcast a device’s current IP address, press and hold the 
RTFM switch for a couple of seconds and then release it.

To restore the factory defaults, complete the following steps:

1. Press and hold the RTFM switch until you hear the device 
announce the words, “restoring defaults” and “rebooting”. 

2. Release the RTFM

 

switch. The device will be restored to the 

factory default settings.

*See the Operations Guide for more information about the features in this section.