Installing the InformaCast Enabled Paging Adapter
Connecting the InformaCast Enabled Paging Adapter
Operations Guide
931767B
CyberData Corporation
8
2.3.4 Page Port Output Connections
2.3.4.1 Pin 1 and 2—Fault Sense Input (Common/Sense)
This input was designed as a method of monitoring an external amplifier that is equipped with a fault
sense relay.
When enabled via the web interface (
Section 2.5.9, "Configure the Fault Detection Parameters"
input (when closed) will play a user uploadable audio file out of the line-out connection and/or place
a SIP call to a pre-determined extension and play that file.
2.3.4.2 Pin 3, 4, and 5—Positive/Negative 600-Ohm Audio Output/Audio Ground
Reference
This output allows direct connection to paging amplifiers requiring a "Page Port" type input that
meets a balanced 600 Ohm 5VPP signal.
2.3.4.3 Pin 6 and 7—Relay Contact (Common/Normally Open)
When enabled on the web interface (
Section 2.5.4, "Configure the Device Parameters"
), every time
an audio file is played out of the local line-out or 600 Ohm output, the relay will close, thereby
enabling amplifiers with a remote turn-on capability to become active.
Table 2-1. Page Port Output Connections
Pin
Description
Pin 1
Fault Sense Input (Common). See
Section 2.3.4.1, "Pin 1 and 2—Fault Sense Input (Common/Sense)"
Pin 2
Fault Sense Input (Sense). See
Section 2.3.4.1, "Pin 1 and 2—Fault Sense Input (Common/Sense)"
.
Pin 3
Positive 600-Ohm Audio Output
a
Section 2.3.4.2, "Pin 3, 4, and 5—Positive/Negative 600-Ohm Audio
Output/Audio Ground Reference"
.
Pin 4
Negative 600-Ohm Audio Output.
a
. See
Section 2.3.4.2, "Pin 3, 4, and 5—Positive/Negative 600-Ohm Audio
Output/Audio Ground Reference"
.
Pin 5
Audio Ground Reference. See
Section 2.3.4.2, "Pin 3, 4, and 5—Positive/Negative 600-Ohm Audio Output/Audio
.
Pin 6
Relay Contact - Common
b
. See
Section 2.3.4.3, "Pin 6 and 7—Relay Contact (Common/Normally Open)"
Pin 7
Relay Contact - Normally Open
b
Section 2.3.4.3, "Pin 6 and 7—Relay Contact (Common/Normally Open)"
a. The 600-Ohm audio output of the page port is also suited for interfaces with lower input impedances.
b. 1 Amp at 30 VDC for continuous loads