Quick Reference
Quick Reference
931549B
© 2022, CyberData Corporation, ALL RIGHTS RESERVED
Wall Mounting Options
Gang Box Mounting Options
Screw
Wall Cutout
on Wall
Pre Drill Holes
121001A
Backplate
Accessor
y
Kit
to J1
Cable
Network
Slot
Opening
Entr
y
Cable
Mounting
Screw (3x)
(Not Provided)
Network Cable
Backplate
Wall Cutout
or Two Gang Box
Backplate accept
Single Gang Box
Wall Cutout
(Not Provided)
Ground Wire
Single Gang Box use two
Screw
121002B
Accessor
y
Kit
Available Mounting Hole
Pick One of Two or Four
for Ground Wire Connection
Two Gang Box use Four
Slot
Entr
y
Cable
Closed
Slots
Cable
Dimensions
Terminal Block Connections
RTFM Button
1.400 [35.6]
4.528 [115.0]
4.528 [115.0]
DIMENSIONS ARE IN INCHES [MILLIMETER]
1
8
Wire (IN)
Tin Leads
Approx. 1/4” or
6mm
Terminal Block
can accept 16 AWG wire
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
3
4
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws
To announce the device’s current IP address:
•
Press and release the RTFM button within a five
second window.
Note
The device will use DHCP to obtain the new
IP address (DHCP-assigned address or
default to IPv4 Link Local if a DHCP server is
not present).
To restore the device to factory default settings:
•
Press and hold the RTFM button for longer than
five seconds until you hear the device announce
that it is restoring the factory default settings.
RTFM button (SW1)