General Hazards

 

 

All  moving  parts  of  the  refrigerator  are  suitably  guarded  any  repairs  and 
maintenance should only be carried out by a qualified professional 

 

 

Electrical Connection

 

 

This cabinet is supplied with a flexible power cable that has a molded 
3  pin  plug  on  the  end.  The  plug  needs  to  be  accessible  once  the 
equipment  is  placed  in  its  final  position.  Do  not  overload  the  power 
supply  (see  rating  label  inside  cabinet  for  power  supply  and  current 
draw) should the plug require replacement please contact a qualified 
electrician. 
 

Unpacking

 

 

Leave  all  packaging  in  place  until  refrigerator  is  in  its  final  position  to  avoid 
damage. When the cabinet is in its final position, carefully remove all packaging 
and  check  for  damage.  Any  damage  should  be  reported  immediately  to  your 
dealer.  All  packaging  should  be  carefully  disposed  of  and  recycled  where 
possible. 
 

Installation

 

 

The cabinet is very easy to 

move around as it’s supplied on castors. If for any 

reason the cabinet has to be laid down, it should always be laid on its back 
and  not  its  side  or  front  to  avoid  damage.  When  lowering  or  raising  the 
cabinet  extreme  care  should  be  taken  as  the  casters  can  cause  the 
cabinet to slip  away  whilst lifting or lowering. A person should  always 
be  standing  at  the  base  of  the  cabinet  whilst  it  is  being  lowered  or 
raised.  Cabinet  should  not  be  plugged  in  for  at  least  1  hour  if  it  has 
been laid down or tipped during installation. 

 

This  product  must  be  placed  on  a  level  floor  to  ensure  the  automatic 
door closing and correct draining of condensate. Once in final position 
lock the two front castors by pushing down on the extended tab.  

 
 
 

Ventilation

 

 

For efficient operation of the cabinet, it is essential that adequate ventilation be provided 
around  the  refrigeration  unit.  The  maximum  recommended  ambient  temperature  (at 
place  of  installation)  is  43°C,  although  the  cabinet  will  generally  use  less  power  when 
installed in a cooler location. Refrigeration equipment generates a lot of heat. Therefore, 
it is very important that the cabinet must be installed with sufficient space around it for 
ventilation and for maintenance access.  Ventilation grills must not be blocked, or even 
partially blocked as this could affect the cabinet

’s performance and life span. 

Содержание CCB 550

Страница 1: ... 1 OPERATING INSTRUCTIONS CCB CCT 550 Glass Door Merchandiser V2 2017 CyberChill Refrigeration P O Box 7200 Baulkham Hills BC NSW 2153 Australia 1300 072 000 www cyberchill com au ...

Страница 2: ...This page is intentionally left blank ...

Страница 3: ...acement 5 Replacing the LED Tube 5 Removing Cassette Bottom Mount 6 Removing Casette Top Mount 7 Initial Start Up 8 Checks 8 Using Your New Piece of Refrigeration Equipment 8 Commissioning Instructions 9 Fault Finding 10 Alarms 11 LAE Controller Wiring Diagrams 12 Notes 13 Contents All information is subject to change without prior notice ...

Страница 4: ...s back and not its side or front to avoid damage When lowering or raising the cabinet extreme care should be taken as the casters can cause the cabinet to slip away whilst lifting or lowering A person should always be standing at the base of the cabinet whilst it is being lowered or raised Cabinet should not be plugged in for at least 1 hour if it has been laid down or tipped during installation T...

Страница 5: ...ED Light Tube The cabinet has one interior side light The side light houses one 12 Watt T5 LED tube which may be replaced without removing shelves or product from the cabinet 1 Disconnect the cabinet from the mains power supply 2 Slide a thin flat head screw driver between the diffuser and the edge its clipped into Remove the side light diffuser by sliding the screw driver down the full length of ...

Страница 6: ...fig 1 3 Lower the kick panel to remove and set aside fig 2 4 Using a flat head screw driver undo the 4 screws on the control fascia and remove fig 3 5 Using a Phillips head screw driver undo the outermost crews securing the lifting handles fig 4 6 Unplug the 4 plugs leading into the electrical compartment fig 5 7 Lower the handles to drop the cassette down and slide out to perform work fig 6 Fig 1...

Страница 7: ... recommended to avoid causing damage fig 2 4 Unplug the 4 plugs into the electrical compartment fig 3 5 Undo the 2 bolts holding the cassette on to the cabinet with a number 13 spanner fig 4 6 The cassette can now be lifted off the cabinet 7 Should works only be required on the evaporator housing proceed with steps 1 2 3 4 and Then 8 8 Undo the 4 bolts holding the insulated lid set aside and proce...

Страница 8: ...rmits stay with the cabinet until the pre set temperature is reached and the condensing unit cuts out Using Your New Refrigeration Equipment The cabinet must reach its preset operating temperature before loading any produce Ensure stored products are evenly distributed on shelves ensuring that no more than 40kg are placed on each shelf Cover all foods ensuring that cooked and raw foods are kept se...

Страница 9: ...ay the set point This setting can then be changed to better meet site conditions by pressing the or buttons Refrigerators have a maximum setting of 10oC and a minimum of 2C The temperature set is the cut out stopping temperature the cut in starting temperature is determined by the differential Defrosting All CyberChill refrigerated cabinets are fitted with a fully automated defrost system that ens...

Страница 10: ...l CyberChill on 1300 072 000 When requesting a service call please find the manufacturers data plate and provide the model serial number and details of any fault codes that are displayed Alarms The controller is equipped with visual and audio alarms Alarm Displayed Description Action Required do Door Open Alarm Close door hc Condenser High Temperature Alarm Check for blockage clean hi High Tempera...

Страница 11: ...Wiring Diagram ...

Страница 12: ...Notes ...

Страница 13: ...34a 1430 R404a 3922 These units contain fluorinated greenhouse gases covered by the F Gas directive Declaration of Conformity References Low Voltage Directive 2006 95 EC EC Machinery Directive 2006 42EC Electromagnetic Compatibility Directive 2004 108 EC Pressure Equipment Directive 97 23 EC RoHS WEE Directive 2002 95 EC ...

Отзывы:

Похожие инструкции для CCB 550