DEFINITIONS FOR ILLUMINATED LED INDICATORS
Icon Name
Alarm
Condition
Using AC
OFF
Normal
Beep twice every 30
seconds
Utility Failure – The UPS is providing
power to battery power-supplied outlets
from its battery.
Using Battery
Rapid beeping every
1/2 second
Utility Failure – The UPS is providing
battery power. Rapid beeping indicates
the unit will run out of power shortly.
Fault Constant
Tone
Battery Overload – Occurs when
connected equipment exceeds the listed
capacity of the UPS. Turn the UPS off,
unplug at lease one piece of equipment
from battery outlets, reset the circuit
breaker and turn the unit on.
Battery Capacity
OFF
3 LED: 75~100%
2 LED: 50~75%
1 LED: 25~50%
1 LED Flash: <25%