7.4 Cycle stop
Proceed as follows:
Activate pedal function to stop the processing cycle. (see par. 6.3).
7.5 Emergency stop
Press one of the emergency buttons on the machine to immediately stop all its functions.
7.6 Restart after an emergency stop
To restore the cycle after an emergency stop:
Resolve the cause that led to the emergency stop.
Deactivate the emergency button, turning the button counter-clockwise.
Press the RESET button.
Restart processing (see par. 7.2).
7.7 Re-start after a black-out
To restart the machine after a black-out:
Perform the operations described in par. 7.1 and 7.2.
The cycle stop only stops the rotation of the rubber rollers while the rest of the machine continues to be in the "start"
conditions.
The emergency stop causes deactivation of the auxiliary circuits and consequently an immediate stop of all machine
movements.
When they are hot, the high temperature rollers can deform if left stationary for prolonged periods of time.
They must always be kept in rotation for cooling.
If they need to be stopped, for example for an emergency stop, restart them as soon as possible.
When they are hot, the high temperature rollers can deform if stopped and left in contact with one another.
If they need to be stopped, move them away from one another.
When heated to a temperature exceeding 60°C, the high temperature rollers must always be in motion.
EXPRESS
USE AND MAINTENANCE MANUAL
EN
MANUAL CODE: 771027010
REVISION: 0
DATE: 29/11/2018
FLEXA S.r.l. - Partial or whole reproduction prohibited without authorisation
40
Содержание CWTLAM-160
Страница 2: ......
Страница 59: ......
Страница 60: ...FLEXA Sr l reserves the right to make technical changes to this manual without prior notice...