![CWS PoolNaturally Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/cws/poolnaturally/poolnaturally_installation-and-product-use-instructions_2701244004.webp)
© 2016
Clear Water Supplies International Limited
Assembly and Use Instructions
Read these instructions thoroughly prior to installation start.
1. Gather recommended parts list or order installation kit.
Lay out all parts in order of assembly
2. Prepare by first applying Teflon tape (not supplied) 3 wraps around each threaded fitting.
Assemble the inflow / outflow ports
3. Verify that a plug is installed at the internal bypass port on the IN side of the dispenser,
then, using typical PVC primer and glue (not supplied) install the 1
½
“x
½
“ SP x FT
bushing (3) to the port labeled IN at the bottom of the contact chamber, then duplicate
actions and install the second 1
½
“x
½
SP x FT bushing (3) to the port labeled OUT.
4. Note: Allow sufficient dry (hardening time) consult your PVC glue container for directions.
5. Assemble one each of the (Teflon taped)
½
” x 2
½
“nipples (4) and
½
” hose barb
adapters(6) screwing each into opposite ends of one of the
½
” FPT utility ball valves(5),
Note: typical tightening is hand tight plus 1/3 turn with a wrench Do not over tighten.
6. Screw this assembled nipple, valve, barb, assembly into the 1
½
“x
½
“ SP x FT bushing
installed at the bottom of the dispenser labeled IN. typical tightening is hand tight plus
1/3 turn with a wrench Do not over tighten. Make sure the valve handle is facing up or in
a position where it can be easily reached after the completed installation.
7. Repeat steps 5 and 6 to the OUT port of the contact chamber.
8. Set contact chamber into its base(2).
9. Optional action: You may choose to: turn the assembled contact chamber and base
upside down and apply a bead of silicone caulking (not supplied) to the underside of the
base where it meets the chamber housing; this will create a more solid connection
between these two parts, after the silicone hardens.
10. Set unit upright and place it at a convenient location among the pool equipment,
preferably on the equipment pad. Noting: unobstructed access to the contact chamber lid
and utility ball valves, also note proper location of the IN and OUT ports. Secure contact
chamber base to the ground with cement screws, if possible.
Connections to pool plumbing
Prior to these next steps: be certain the pool equipment power is off and the utility ball
valves (if any) are closed.