6-STOP/choose parameters/erase alarms button
7-START/choose parameters button
8-Start programming /confirm parameters settings button
9-Hot water pump work indicator
Picture 1. Front panel of the RK-2001W controller
Basic operation of the controller is carried out by setting the desired temperature
with boiler thermostat knob, other functions are carried out according to parameters
programmed in service mode. The change in the boiler temperature setting is
shown on the display for a few seconds, e.g. [C 55] and this value means the
temperature of the water in the boiler which the controller will be trying to achieve.
You can also check this value by pressing OK button for a short time. After
pressing START button the fan starts to work and the control process begins.
STOP button stops the fan for example to add fuel.
If the controller is not in user or service mode the display shows water temperature
in the boiler and the last character on the display defines the mode which the
controller is currently in:
for example:
[50º-] - STOP mode
[50ºC] - WORK mode
[50ºc] - hold up of burning in WORK mode
[50ºU] – heating of hot water in SUMMER mode
[50°u] - hold up of burning in SUMMER mode
[50ºd] – total bacteria control – heating up of hot water up to
75ºC.
-
Setting up the user parameters.
Holding OK button enters the user mode and allows reviewing and is indicated by
fast flashing of the room thermostat indicator. You can look through the parameters
with < and > arrow buttons. After choosing the desired parameter you can switch to
the change mode of the parameter by pressing OK button - it is indicated by the
value of the parameter flashing.
Change of the parameter is done by pressing - or + buttons. You can confirm new
settings by pressing OK button and after that the controller allows choosing another
parameter (with < > buttons). If you do not want to change the parameter value
with the < or > button choose [End] and press OK or wait for 1 minute – the