3
accuracy. Move the device to another location if interference is determined.
• When not using the Blood Pressure Monitor for extended lengths of time, remove
the batteries to avoid potential battery leakage and damage to the monitor.
• When replacing the batteries, ensure all the batteries are replaced simultaneously
to avoid battery damage and potential damage to the monitor. Microlife USA does
not recommend using rechargeable batteries.
• To avoid inaccurate measurements and to lessen any discomfort from Cuff
pressure, ensure the Cuff is placed correctly on the limb and fits correctly when
snug (not tight), as indicated by markings with the Cuff.
• Consult your physician in cases of frequent irregular heartbeat detections.
• This Risk Indicator feature is provided in order to help you understand your
potential blood pressure risk. However, this feature is neither a diagnosis nor a
substitute for a medical examination. It is important to consult with your physician
to determine your risk.
DO NOT:
Drop this device or expose it to strong vibrations; sensitive components may be
affected resulting in inaccuracies and/or operational issues.
Use the Blood Pressure Monitor outside of its specified operation temperature and
humidity rating, or if stored outside of its specified storage temperature and
humidity rating. Avoid storage in direct sunlight.
Use this device in a moving vehicle; inaccurate measurements may result.
Use third party accessories. Only use Microlife authorized accessories, such as
cuffs or AC adapters, as those not approved for use with the device may provide
inaccurate measurements, injury, and/or damage the device.
STANDARDS
In addition to the standards stated in the Instruction Manual:
• This medical device is compliant with medical device and non-invasive blood
pressure monitor standards IEC 60601-1, IEC 60601-1-2, IEC 60601-1-11, and
AAMI/ANSI/IEC 80601-2-30, and
• Electromagnetic standards IEC 60601—1-2 along with FCC Part 15, and
• Clinical Testing per standard ISO 81060-2:2013 was conducted on blood pressure
device using the same measurement technology.
Please note: According to international standards, your monitor should be checked
for accuracy every 2 years.
CVS-MW1-4Y IB-080421-FINAL.qxp_MLU3AC1-JAN05-2 8/9/21 12:58 PM Page 3
Содержание 800 Series
Страница 2: ...CVS MW1 4Y IB 080421 FINAL qxp_MLU3AC1 JAN05 2 8 9 21 12 58 PM Page 2 ...
Страница 35: ...33 CVS MW1 4Y IB 080421 FINAL qxp_MLU3AC1 JAN05 2 8 9 21 12 58 PM Page 33 ...
Страница 69: ...CVS MW1 4Y IB 080421 FINAL qxp_MLU3AC1 JAN05 2 8 9 21 12 58 PM Page 67 ...
Страница 70: ...BP3MW1 4Y CVS 0821 4 CVS MW1 4Y IB 080421 FINAL qxp_MLU3AC1 JAN05 2 8 9 21 12 58 PM Page 68 ...