www.winstonindustries.com | 1.800.234.5286
HBB HOLD & SERVE DRAWER
4
GENERAL INSTALLATION
Install appliance on a solid, flat, level surface in a location
where ambient temperatures will not exceed 100oF and
away from grease laden vapors from other appliances. For
proper ventilation of the appliance, allow 2 inches clearance
on all sides, particularly around any ventilation holes. Plug
the appliance into a properly grounded outlet of the correct
amperage as indicated by the Appliance ID Label. Please
read detailed installation instructions that follow.
WATER REQUIREMENTS
In order to operate properly, the evaporator in this
appliance must be filled with clean, potable water.
WARNING: Operation of Water Fill System requires that
evaporator be filled to water line prior to turning switch
on.
As water evaporates, minerals in the water will deposit on
the surface of the evaporator. These mineral deposits will
inhibit the transfer of heat. Deposits can also degrade and
damage stainless steel. To avoid mineral deposits clean the
appliance daily. It is advisable to contact your water utility for
advice on minimizing deposit buildup.
INSTALLING AUTO WATER FILL
Insert tubing and push
fully
into the connector. (See
drawing at right.) Once
seated, try to pull the
tubing out of the connector
so that the capture ring
comes out (about 1/16
"
(1.6mm)) and the tubing
cannot be removed.
____________________________________________
!
CAUTION:
High Temperature Hazard
Can cause damage to appliance >>
Fill evaporator with water
prior to turning power on, and do not allow evaporator to run dry.
____________________________________________
THIS APPLIANCE MUST NOT BE ALLOWED TO RUN DRY.
HEAT DAMAGE TO THE WATER VALVE MAY RESULT.
The maximum incoming water temperature may not
exceed 140
°
F (60
°
C) and the incoming water pressure
must be between 20 and 150 psi.
For locations with hard water, add one tablespoon (15ml) of
white vinegar or lemon juice to water to help minimize scale
buildup. Please consider contacting your local water
authority to obtain advice on possible water treatment to
protect the appliance. Some water supplies are high enough
in chemical content to be capable of damaging stainless
steel (if used untreated). The evaporation process can
concentrate the chemicals in the water to a level which
could cause a damaging reaction with the stainless steel.
VENTILATION REQUIREMENTS
Ventilation Clearances:
To operate properly, the appliance
will need sufficient space for air circulation. Allow at least 2
"
(51mm) clearance on all sides, particularly around ventilation
holes. Care should be taken to prevent placing the appliance
close to anything combustible. It must be installed with its
supplied feet or legs. Countertop appliances supplied
without feet or legs may be placed directly upon a counter-
top of noncombustible material. In this situation, the
appliance may have to be sealed to the countertop with a
food-grade silicone sealant (check local health codes).
Appliances may be stacked upon each other using only a
Winston supplied stacking kit and following the instructions
enclosed with the kit. Your warranty may be void if you do
not adhere to these ventilation requirements.
____________________________________________
!
CAUTION:
High Temperature &
Grease Hazard
Can cause damage to appliance >>
Avoid
placing appliance near high heat or in grease-laden atmosphere.
____________________________________________
Do not place appliance in an area where ambient
temperature (air temperature around the appliance) exceeds
100°F (38°C). A heat shield may be required to prevent
excessive heat exposure and grease-laden vapors from
affecting the appliance if adjacent to heat, vapor, or grease
generating devices (such as grills, steamers, ovens, etc.).
Excess heat and grease inside the appliance cavities may
cause electrical components to fail.
Vent Hood:
Generally this appliance does not need to be
installed under a mechanical ventilation system (vent hood).
Check local health and fire codes for requirements specific to
your location.
PUSH
HERE
APPLIANCE
WALL
TUBING CAPTURE RING