AC/DC MODELS
AC/DC MODELS
DC-ONLY MODELS
(AC Operation)
(DC Operation)
Input Voltage
20 to 264 V ac, 50/60 Hz
15 to 30 V dc
10 to 30 V dc
(15 to 24 V dc above 55° C/131° F)
(10 to 24 V dc above 55°C/131° F)
Power Dissipation
1.5 W maximum
1.5 W maximum
1 W maximum
Output Type
VMOS (bi-directional)
NPN (sink)
NPN and PNP (dual outputs)
Current Switching
300 mA maximum
300 mA maximum
PNP (source): 100 mA maximum;
Capacity
NPN (sink): 250 mA max.
(120 mA max. above 55° C/131° F)
Voltage Switching
375 V peak maximum
375 V peak maximum
30 VDC maximum
Capacity
Off-State Leakage
250
µ
A typical
250
µ
A typical
10
µ
A maximum
500
µ
A maximum
500
µ
A maximum
Surge Current
2 A maximum
2 A maximum
1 A maximum
On-State Voltage
- - -
1.8 V at 10 mA; 3.5 V at 300 mA
NPN: 400 mV at 10 mA,
Drop
1.5 V at 250 mA;
PNP: 2.8 V at 100 mA
Response Time
8 mS
3.5 mS
Short Circuit
Sensor will turn off immediately when a short or overload is detected (Indicator LED will flash).
Protection
Turn power OFF and back ON to reset.
IMPORTANT: During installation, correct power connections must be made first to ensure fail-safe short
circuit protection of the outputs.
Light/Dark Operation Switch selectable on detector
Temperature Range
Operating and Storage; Source: -20° to +70° C (-4° to +158° F); Detector: -40° to +70° C (-40° to +158° F)
Material of
Lens: Polycarbonate; Cable jacket: PVC; Body: Structural polyurethane foam
Construction
(do not expose to concentrated acids, alcohols, or ketones)
Cable/Connector
6-foot cable, 3-wire (ac/dc models), 4-wire (dc-only models); Micro Connector, 4-pin male
Vibration and Shock
Vibration: 30 g over 10 Hz to 2 kHz; Shock: 100 g for 3 mS 1/2 sinewave pulse
Indicator LED
Source: Lights when power is ON; Detector: Lights steady when output is ON, Flashes when short circuit
protection is in latch condition
Sunlight Immunity
10,000 foot-candles
Enclosure Ratings
NEMA 1, 2, 3, 4, 4X, 6, 12, and 13
(Our products conform to NEMA tests as indicated, however, some severe washdown applications can
exceed these NEMA test specifications.If you have questions about a specific application, contact our
Applications Department.)
Approvals
Contact factory for the latest list of approvals