background image

109818-100  Rev 05

Cutler-Hammer

Instruction Manual:
Comet

®

 Series Thru-Beam Sensors

WARNING

Models covered in this manual:

AC/DC  Models  w/  Cable

AC/DC  Models  w/  Connector

DC-only Models w/ Cable

DC-only Models w/ Connector

Viewing Style:

Forward

Right Angle

Forward

Right Angle

Forward

Right Angle

Forward

Right Angle

Sources

Wide Beam

11100A6513

11100R6513

11100AQD03

11100RQD03

11100A6517

11100R6517

11100AQD07

11100RQD07

Long Range

11102A6513

---

11102AQD03

---

11102A6517

---

11102AQD07

---

Detectors

Wide Beam

12100A6513

12100R6513

12100AQD03

12100RQD03

12100A6517

12100R6517

12100AQD07

12100RQD07

Long Range

12102A6513

---

12102AQD03

---

12102A6517

---

12102AQD07

---

THESE PRODUCTS ARE NOT DESIGNED, TESTED, OR RECOM-
MENDED FOR USE IN HUMAN SAFETY APPLICATIONS.

USE #4 MOUNTING HARDWARE ONLY! LARGER HARDWARE
WILL DAMAGE THE SENSOR AND MAY CREATE AN ELECTRI-
CAL SHOCK HAZARD. TIGHTEN THE HARDWARE JUST TO THE
SENSOR BODY SO THAT NO DEFLECTION OF THE BODY
OCCURS.

DURING INSTALLATION, CORRECT POWER CONNECTIONS
MUST BE MADE FIRST TO ENSURE FAIL-SAFE SHORT CIRCUIT
PROTECTION OF THE OUTPUTS. REFER TO THE WIRING
DIAGRAMS IN THIS MANUAL.

DO NOT USE TOOLS TO APPLY TORQUE DIRECTLY TO SENSOR
BODY. ALIGN SENSOR BY HAND BEFORE TIGHTENING
MOUNTING HARDWARE.

THE GAIN AND LIGHT/DARK ADJUSTMENT POTS ARE 3/4
TURN POTS. ANY RESISTANCE ENCOUNTERED WHILE
ADJUSTING THESE POTS INDICATES YOU HAVE REACHED THE
ADJUSTMENT LIMIT STOP. TURNING PAST THIS STOP WILL
DAMAGE THE SENSOR.

USE ONLY A SUITABLE ADJUSTMENT TOOL OR FLATBLADE
SCREWDRIVER WHEN TURNING ADJUSTMENT POTS. SHARP
OBJECTS CAN DAMAGE THE POT AND RESULT IN ELECTRICAL
SHOCK.

AC/DC CONNECTOR VERSION SENSORS ARE EQUIPPED WITH
AN AC-TYPE CONNECTOR. THE USE OF DC POWER WITH AC-
TYPE CONNECTORS MAY NOT CONFORM WITH ESTABLISHED
STANDARDS.

INTRODUCTION

Thru-beam sensors consist of a source and detector posi-
tioned on opposite sides of a detection zone. The source emits
infrared and visible red light, which is received by the detector.
The detector output switches when this beam of light is either
blocked (when set for dark operation), or completed (light
operation). Note that a wide beam source will not work with a

Right Angle 
Viewing

Forward 
Viewing

Mounting
sensor 
using 
jam nuts.

Mounting  

sensor using 

#4 hardware.

long range detector and a wide beam detector will not work
with a long range source .

This manual covers both forward viewing and right angle
viewing models. Although the units differ in the location of the
lenses, the basic fundamentals of installation, setup, and

operation are nearly identical. The two types of sensors may be
intermixed with no change in optical performance.

MOUNTING

The Comet sensor features a threaded housing and includes
jam nuts and washers. This allows mounting into any 0.75 inch
hole, or a model 6161A-6501 “L” bracket. Use caution to avoid

cross-threading the jam nuts on the sensor body. Tighten nuts
to less than 4 N•m (36 in.-lbs. or 3 ft.-lbs.) torque to avoid
stripping threads.

A second mounting method is to use #4 hardware in the 0.125
inch diameter mounting holes in the flat sides of the sensor.
This is ideal for mounting the Comet against a wall, piece of
equipment, rail, mounting bracket, etc.

Содержание 11100A6513

Страница 1: ...R FLATBLADE SCREWDRIVERWHENTURNINGADJUSTMENTPOTS SHARP OBJECTS CAN DAMAGE THE POT AND RESULT IN ELECTRICAL SHOCK AC DC CONNECTOR VERSION SENSORS ARE EQUIPPED WITH AN AC TYPE CONNECTOR THE USE OF DC POWER WITH AC TYPE CONNECTORS MAY NOT CONFORM WITH ESTABLISHED STANDARDS INTRODUCTION Thru beam sensors consist of a source and detector posi tioned on opposite sides of a detection zone The source emit...

Страница 2: ...e brightest The detector must be placed within the source beam pattern the area containing all the light rays emitted by the source The source must be placed within the detector field of view for the detection system to operate Only the light source rays that travel in a straight line to the receiver the diameter of the lens will be detected An object must fully block this beam in order to be dete...

Страница 3: ...IRING DIAGRAMS For wiring cable versions the color codes shown are the actual wire colors emanating from the sensor For connector ver sions the pin numbering and color codes shown are typical of several manufacturers however variations are possible In case of discrepancies rely on function indicated and pin location rather than pin number or color code AC DC Models AC Connection AC DC Models DC Co...

Страница 4: ...nsor will turn off immediately when a short or overload is detected Indicator LED will flash Protection Turn power OFF and back ON to reset IMPORTANT During installation correct power connections must be made first to ensure fail safe short circuit protection of the outputs Light Dark Operation Switch selectable on detector Temperature Range Operating and Storage Source 20 to 70 C 4 to 158 F Detec...

Отзывы: