PRO SERIES
PS-1030
•
PS-1430
•
PS-1930
20
SECTION 4
TECHNICAL REFERENCES
4.3 | CONTROL BOARD DIAGNOSTIC
When using the LED for diagnosis, note that a
DUAL FLASH code is indicated. The LED will flash
on/off a certain number of times, pause off for
a short delay, then flash on/off a second certain
number of times, followed by a much longer
pause off. The sequence will then repeat.
EXAMPLE:
The LED flash code 3-2 will look like:
on/off/on/off/on/off-short-delay/on/off/on/off-
long-delay/repeat
FIGURE 6: LED Light Diagnostic Location
LED Code Possible Cause
Fast Flash Control Module is not calibrated, Do not operate unit.
Steady
Unit has just been powered on. You may need to wait for initialization, then re-select function.
Ready to operate, things should be working normally.
A function is selected but the enable trigger is not squeezed.
1-1
The control module is not calibrated. Do not use this unit.
2-1
The key switch selector switch indicate the mode in which the TS100 must operate. If neither
input is active, or if both are active together, the TS100 does not know how to function.
Check key switch and wiring to P15-1 and P12-1.
2-2
A safety feature is locking functions or a switch has failed.
Check that platform is not overloaded, operating on a level surface, and pothole guards deploy.
Check that joystick is neutral when powered on.
Check that joystick trigger is not closed for too long without selecting a function.
Check for failed joystick, selector switches, and up/down switches.
3-x
There is a problem with the drive contactor or valve wiring, or with the motor power wiring;
disconnect connector P9 to see if the problem is caused by drive contactor or valve wiring (if
the fault clears, check for an illegal B+ supply in to P9)
Check motor power wiring; with the drive contactor open the B+ power terminals should be at
10V-15V (significantly lower than B+) If the LED is steady at power-on, and the fault (3-5) occurs
after a delay when attempting to drive or lift, the motor may be stalled and causing an overload
of the TS100 or there is a power wiring error like connecting the B+ cable to a motor stud
FIGURE 7: EZ Cal Handheld Controller
If a handheld controller (Part no: ELEC-646-5)
is available, it will display error codes and their
description
Содержание HY-BRID LIFTS PRO PS-1030
Страница 11: ...11 MAINTENANCE TROUBLESHOOTING MANUAL PS5 0 M REV B THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 36: ...PRO SERIES PS 1030 PS 1430 PS 1930 36 SECTION 6 TROUBLESHOOTING FLOWCHARTS 6 4 ELEVATE CIRCUIT ...
Страница 37: ...37 MAINTENANCE TROUBLESHOOTING MANUAL PS5 0 M REV B SECTION 6 TROUBLESHOOTING FLOWCHARTS ...
Страница 44: ...PRO SERIES PS 1030 PS 1430 PS 1930 44 SECTION 9 INSPECTION REPAIR LOG DATE COMMENTS ...
Страница 45: ...45 MAINTENANCE TROUBLESHOOTING MANUAL PS5 0 M REV B SECTION 9 INSPECTION REPAIR LOG DATE COMMENTS ...
Страница 46: ...PRO SERIES PS 1030 PS 1430 PS 1930 46 SECTION 9 INSPECTION REPAIR LOG DATE COMMENTS ...
Страница 47: ...47 MAINTENANCE TROUBLESHOOTING MANUAL PS5 0 M REV B SECTION 9 INSPECTION REPAIR LOG DATE COMMENTS ...