IMPORTANT SAFETY PRECAUTIONS 

 

This residential elevator is designed and manufactured in accordance with ASME A17.1 Part 5, safety 

code for elevators and escalators.  It is intended for use in a private residence only and not for commercial or 

public use.  Its use is to be limited and under the supervision of the homeowner who is responsible for ensuring 

the safety of the elevator operation as well as with persons using the elevator. 

 

 

 

 

 

The following is a list of safety instructions that must be understood and followed by everyone  

operating the elevator.  Failure to follow these instructions can result in severe injury or death.

 

 

Read and understand the contents of this manual prior to attempting to operate the elevator. 

 

Never allow children to access the machine equipment or operate the elevator unattended. 

 

Never overload the elevator beyond its rated capacity.  Do not use the elevator to transport 

freight. 

 

Always watch your step when entering or exiting the elevator.  Be certain that the elevator sill is 

level with the landing sill. 

 

Never extend your hands or feet outside the cab while the elevator is moving or between floors. 

 

Never use the elevator in case of smoke or a fire. 

 

Never operate the elevator if you should detect any abnormal operation, unusual sounds, or 

recognize damage to any parts of the elevator. 

 

Never bypass any safety devices. 

 

Never lean against the car doors or landing doors. 

 

Make certain that the telephone and alarm located in the elevator cab are operable at all times. 

 

Never enter the hoistway above or below the elevator. 

 

Never remove covers from the control equipment. 

 

Always keep equipment room locked and keep access to the equipment clear in case of an 

emergency. 

 

The elevator hoistway and machine area must be kept dry. 

 

Never try to extract anyone from the elevator if it has stopped between floor levels. 

 

Never allow pipes, conduits, ducts, and other unrelated utilities to run through the elevator 

hoistway. 

 

Never attempt to repair or service the elevator yourself.  Call an authorized Custom Elevator 

Representative for service.

 

     

                                    

 

              1                                    

 

 

 

 

 

 

This safety alert symbol will be found throughout this 

manual and on various components of the elevator.  

This symbol is used to alert you of a hazard that could  

cause injury to yourself or others and what you can do  

to avoid the hazard.

 

Содержание HYD-7.540

Страница 1: ...July 16 2014 Roped Hydraulic Residential Elevator OWNER S MANUAL Authorized Custom Elevator Representative Company Name Address Phone Model HYD 7 540 Serial Installation Date...

Страница 2: ...y precautions troubleshooting maintenance and warranty information that must be read and understood prior to operating your elevator This manual should be retained for future reference Any scheduled m...

Страница 3: ...your hands or feet outside the cab while the elevator is moving or between floors Never use the elevator in case of smoke or a fire Never operate the elevator if you should detect any abnormal operat...

Страница 4: ...tructions 4 Emergency stop switch The elevator will stop movement when pulled Remember to always push the button in during normal operation otherwise the elevator will not run 5 Alarm push button This...

Страница 5: ...the door interlock system A working telephone must be maintained inside the elevator car at all times If the elevator should run with the car door s open call for service immediately Avoid operating...

Страница 6: ...THE CAR CONTROLS After entering the elevator from a landing remember to close the landing door and car door s securely before attempting to operate the elevator NOTE If your elevator has an automatic...

Страница 7: ...age An accurate log may be necessary when validating a warranty claim TROUBLESHOOTING If the elevator should fail to operate after following the operation instructions in this manual check the followi...

Страница 8: ...SERVICE MAINTENANCE LOG PREVENTATIVE MAINTENANCE TECHNICIAN S INITITIALS DATE REASON FOR SERVICE WORK PERFORMED COMPANY PERFORMED BY 6...

Страница 9: ...acitor Run 950 lb capacity PUMP Rotary Screw Constant Displacement VALVE Blain Hydraulic EV 100 4 Coil 2 Speed JACK ASSEMBLY 2 3 4 Piston 4 1 2 Cylinder Single Stage 3 7 16 Piston 5 9 16 Cylinder Sing...

Страница 10: ...ghtening fire etc or exposure to abnormal conditions of temperature moisture dirt corrosion etc In addition failure to run or damage caused by inadequate or interruption of electrical service resultin...

Страница 11: ...Custom Elevator Manufacturing Co Inc Customer Service Dept P O Box 749 5191 Stump Road Plumsteadville PA 18949 Toll Free 888 443 2800 Phone 215 766 3380 Fax 215 766 3385 Email info customelevatorinc c...

Страница 12: ...10 WIRING DIAGRAM NOTE T his diagram is intended for use by trained persons having necessary skills and experience in servicing this equipment...

Отзывы: